E. Setting the Temperature of Your Swimming Pool Heat Pump
1. If your heat pump fan and compressor is running press the START/STOP button to
make the heat pump enter its standby mode.
2. Press the set button repeatedly until SET NO 01 shows with the set point temperature
in degrees C.
3. Use the up arrow button and the down arrow button to adjust the set point temperature
to your desired point. If you have a liner type swimming pool do not exceed the
recommended maximum temperature for the liner (often 28°C).
4. The display will return to the standby mode after a few seconds.
5. Restart the heat pump by pressing the START/STOP button.
6. After the 2 – 3 minute delay the heat pump will re-start with the new set temperature.
F. Checking the Status of Your Swimming Pool Heat Pump
1. When the heat pump is running press the up or down arrow to scroll through the status
readings as below.
2. IN & OUT are the respective temperatures at the water inlet and outlet. Note that when
you have a good flow rate through the heat pump the difference may be less than 1°C
so it appears there is no difference.
3. P1 is the temperature of condenser 1, P2 is the temperature of condenser 2. Note that
some models have just one condenser so a reading may not be present for both P1 &
P2.
4. ROOM is the temperature of the air around the heat pump.