6
Revised 2019
RECOMMENDED MAINTENANCE
* BEFORE CLEANING, TURN OFF THE UNIT, UNPLUG
AND LET THE MACHINE COOL DOWN *
NON-STICK COVER & SEAL PLATE
Due to the advancement of this technology, it is important to keep the non-stick cover in good condition. It is recommended
to replace the non-stick cover at least once every three months to protect the seal plate and maintain a sanitary surface. The
seal plate has been designed to provide long life performance when it is properly maintained. The seal plate should not be
used as a cutting surface, any punctures will render the seal plate ineffective and void the warranty.
The non-stick cover is used to create a sanitary, stick free sealing surface. Non-stick covers are porous, so liquid can
permeate the cover and burn off on the hot plate.
The non-stick cover should be replaced if the surface is soiled, or holes, punctures, excessive wear, or damage is present.
The seal plate can be cleaned with a mild degreaser. Spray the degreaser onto a soft rag or paper towel and clean the plate
while cool.
CLEANING THE CUT OFF ROD
Make sure that the unit is turned off and the cut off rod is cool to the touch.
Cover the surface with paper towels to protect it from over spray and debris.
Spray the cut-off rod generously with an FDA approved degreaser.
After soaking, lightly scrub the surface of the cut-off rod with a scour pad (Scotch-Brite™ type pad).
Wipe the surface clean of debris and residue with clean paper towels or cloths.
Repeat degreaser as needed until the rod is clean.
CLEANING THE UNIT
The 200ES can be completely wiped down using mild cleaning detergent and soft rags or paper towels. Do not hose down
or submerge the unit.