MACHINE TECHNOLOGY & COMPONENTS 

THERMISTOR TEMPERATURE CONTROL 

 

Due to the rapid response of the seal plate and residual heat that can remain from previous cycles, a thermistor is 
incorporated as a temperature control device. The heat cycle can be shorter than 3 seconds when residual heat is present in 
the seal plate. The thermistor is located inside of the seal plate assembly.  

STAINLESS STEEL BRIDGE 

 

The wrapper comes with a stainless steel bridge (1) that can 
be utilized as a working surface while preparing products. 

 

The stainless steel bridge is 

not 

recommended as a cutting 

surface.   

TWO ROLL CAPACITY 

 

The wrapper can hold two 20” rolls of film (2). The rolls should 
be mounted and threaded as shown on page 5. There is also 
a threading diagram located on the right side of the unit. 

 

OPERATOR INDICATOR LIGHT 

 

A dual-colored light (3) will change from yellow, when the 
plate is heating, to red when the plate is at film sealing 
temperature. 

 

GFCI 

 

To maintain circuit protection and integrity, a GFCI (4) is  
installed in the electrical box, and may need to be reset if  
wrapper gets wet or other ground faults arise.  Do NOT 
reset the GFCI, if visible seal plate damage is present.  

*200ES pictured with optional Paper Cutter 

Summary of Contents for 200ES

Page 1: ...Revised 2019 READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING EQUIPMENT OPERATING SERVICE PARTS MANUAL 200ES ENERGY SMART WRAPPER 200ES C6AXXXB pictured with optional Paper Cutter Certified...

Page 2: ...Electrical Requirements 3 Preliminary Setup 5 Cradle Mount Film Setup Recommended Maintenance 6 Guide For Optional Paper Cutter 7 Troubleshooting Guide 8 Control Board Assembly 10 Service Parts Inform...

Page 3: ...oto eye on the seal plate This feature ensures that the seal plate will consume energy only when there is a demand by an operator Do NOT use the seal plate as a cutting surface this will damage the he...

Page 4: ...le preparing products The stainless steel bridge is not recommended as a cutting surface TWO ROLL CAPACITY The wrapper can hold two 20 rolls of film 2 The rolls should be mounted and threaded as shown...

Page 5: ...f the roll counter clockwise and go in between the two rollers it sits on Pull film under the film guide roller 1 and up through the film selector rollers starting with the nearest slot to the hot pla...

Page 6: ...ermeate the cover and burn off on the hot plate The non stick cover should be replaced if the surface is soiled or holes punctures excessive wear or damage is present The seal plate can be cleaned wit...

Page 7: ...ack idle roller 1 and the tension roller 2 Thread the paper counterclockwise down under the tension roller 2 then up and through the mouth 3 of the paper cutter Use the slot hole on the cutter to grab...

Page 8: ...reaker tripped 1 Remove Non Stick Cover and inspect the Seal Plate for the following defects Punctures or cuts Burn marks Discoloration If these defects are present replace seal plate 2 If seal plate...

Page 9: ...Eye 3 If green light is NOT illuminated when power is ON check Control Board to determine if Photo Eye or Control Board is faulty Verify the control board is working 1 Check the voltage on Pin 1 of th...

Page 10: ...10 Revised 2019 CONTROL BOARD ASSEMBLY NEUTRAL HEATER OUT 24V 0V AUX PRODUCT DETECTION THERMISTOR THERMISTOR 120 VAC...

Page 11: ...11 Revised 2019 CONTROL BOARD ASSEMBLY...

Page 12: ...Cover 6 x 15 2 1 5901 001 Non stick Cover 8 x 15 3 1 6137 149 Replacement 6 x 15 Seal Plate Kit 4 1 6137 150 Replacement 8 x 15 Seal Plate Kit 5 1 6137 094 Hot Rod Replacement Kit Includes 1 Square Bo...

Page 13: ...ammed 8 x 15 Energy Smart Control Board Programmed 2 1 6340 070 Circuit Board Mounting Kit Includes 4 Plastic Clip Stand Offs 3 1 1875 055 Terminal Block 4 1 1815 030 1A Circuit Breaker 5 1 1815 031 2...

Reviews: