4
Revised 2019
MACHINE TECHNOLOGY & COMPONENTS
THERMISTOR TEMPERATURE CONTROL
Due to the rapid response of the seal plate and residual heat that can remain from previous cycles, a thermistor is
incorporated as a temperature control device. The heat cycle can be shorter than 3 seconds when residual heat is present in
the seal plate. The thermistor is located inside of the seal plate assembly.
STAINLESS STEEL BRIDGE
The wrapper comes with a stainless steel bridge (1) that can
be utilized as a working surface while preparing products.
The stainless steel bridge is
not
recommended as a cutting
surface.
TWO ROLL CAPACITY
The wrapper can hold two 20” rolls of film (2). The rolls should
be mounted and threaded as shown on page 5. There is also
a threading diagram located on the right side of the unit.
OPERATOR INDICATOR LIGHT
A dual-colored light (3) will change from yellow, when the
plate is heating, to red when the plate is at film sealing
temperature.
GFCI
To maintain circuit protection and integrity, a GFCI (4) is
installed in the electrical box, and may need to be reset if
wrapper gets wet or other ground faults arise. Do NOT
reset the GFCI, if visible seal plate damage is present.
4
*200ES pictured with optional Paper Cutter