4
FIGURE 01: DIMENSIONS
2.0 TECHNICAL SPECIFICATIONS
Electrical Rating
3.0kW @ 240V/ 2.75kW @ 230V
Capacity
30 and 50 litres
Weight (50 Litre)
69.3kg (full)
Weight (30 Litre)
42.5kg (full)
Operating pressure
0.35 MPa (3.5 bar)
Rated pressure
0.6 MPa (6.0 bar)
Expansion vessel charge pressure
0.35 MPa (3.5 bar)
Expansion relief valve setting
0.6 MPa (6.0 bar)
Minimum supply pressure
0.08 MPa (0.8 bar)
Maximum supply pressure to PRV
1.6 MPa (16.0 bar)
Temperature / Pressure Relief Valve
90°C / 0.7 MPa (7.0 bar)
50 Litre
30 Litre
Dimension
888
616
A
937
665
B
1060
788
C
778
506
D