background image

   

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION AND USER MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Swimming Pool Heat Pump 

Thank 

you for choosing our product and trusting our company.   

This  manual  is  to  provide  you  with  necessary  information  for  optimal  use  and 

maintenance, please read it carefully and keep it for subsequent use.   

Swimming Pool Heat Pump 

Thank 

you for choosing our product and trusting our company.   

This  manual  is  to  provide  you  with  necessary  information  for  optimal  use  and 

maintenance, please read it carefully and keep it for subsequent use.   

Summary of Contents for THP05NP

Page 1: ...with necessary information for optimal use and maintenance please read it carefully and keep it for subsequent use Swimming Pool Heat Pump Thank you for choosing our product and trusting our company T...

Page 2: ...de 5 Transport it in proper manner 5 Determining Optimum installation position 5 Water pipe connection 8 Electric connection 8 Trial after first installation 10 Operation guide 11 LED controller 11 Te...

Page 3: ...rom the fan Never place your hand or any other object in the air inlet or outlet of the heat pump Important features of this product Water Flow Switch The water flow switch contacts are closed when pr...

Page 4: ...pressure in the sealed refrigeration system to protect against certain conditions that could be detrimental to compressor life The switch shuts the unit down in the event of loss of refrigerant or no...

Page 5: ...notice Please refer to nameplate on each machine for accurate information Model THP05NP THP08NP THP10NP THP12NP THP14NP THP17NP Function Heating capacity kW air 26 water 26 5 0 7 5 9 6 14 0 14 0 17 0...

Page 6: ...C D E F G H THP05NP 315 429 312 340 800 250 76 558 THP08NP 315 429 312 340 800 220 76 558 THP10NP 315 590 312 340 961 280 77 658 THP12NP 315 590 312 340 961 320 77 658 THP14NP 395 590 392 420 961 310...

Page 7: ...eration think about the following factors when choose the proper place Avoidance of air recirculation Easy for wire and pipe connection and Water pipe line of long water lines not longer than 10m from...

Page 8: ...le air intake No less than 2500mm clearance on the air outlet is required to prevent recirculation of air We recommend not to place the unit underneath eaves decks or porches as this causes recirculat...

Page 9: ...may consider protecting your heat pump by planting shrubbery or a privacy fence between the unit and the prevailing beachfront wind 4 When the machine is running there will be condensation water disch...

Page 10: ...iring must be handled by a professional technician according to the circuit diagram as following Connect the heat pump to appropriate power supply and the voltage should comply with the rated voltage...

Page 11: ...ter must be increased The signal cable can be extended to 50m at most MODEL THP05NP THP08NP THP10NP THP12NP THP14NP THP17NP Breaker Rated Current A 6 15 15 15 20 25 Rated Residual Action Current mA 30...

Page 12: ...ess power on off on LED controller to turn on off machine During the first start of machine please check if there is any water leakage in the piping connection system Then set suitable temperature Aft...

Page 13: ...e code 1 Operation Display The display shows Temperature of the swimming pool water when the machine is on 2 Water temperature setting A Available no matter the machine is on or off B Press the key or...

Page 14: ...etting E Check the air inlet and outlet Trial A The user must Start the Pump before the Machine and Turn off the Machine before the Pump or the machine will be damaged B The user should start the pump...

Page 15: ...ectrical leakage please switch off the machine immediately and contact the local dealer Don t try to repair it yourself E Don t use or stock combustible gas or liquid such as thinners paint and fuel t...

Page 16: ...ally So please switch off the power supply when there is a power cut and reset temp when power is restored C Please switch off the main power supply in lightning and storm weather to prevent from mach...

Page 17: ...th household detergents or clean water NEVER use gasoline thinners or any similar fuel C Check bolts cables and connections regularly Cut off power supply of the heater before cleaning examination and...

Page 18: ...g and contract on cooling of the heat exchanger when temperature varies Automatic start or stop Check whether there is mal function on the timer Recheck Heat pump does not run A Power supply failure B...

Page 19: ...n the PC board Contact your dealer 5 PP 1 Pool water temp sensor failure Contact your dealer 6 PP 2 Heat only type Exhaust temp sensor failure Contact your dealer 7 PP 3 Heating coil pipe temp sensor...

Page 20: ......