18.14 Pressure Sensor
•
Read the notes at the head of this section before commencing
any work on the appliance.
•
Disconnect and remove the sensor cable and sensor from
the hydroblock. (
fi
gure 48)
•
Fit the replacement pressure sensor in reverse order ensuring
the gasket is correctly
fi
tted. (Replace the gasket if damaged)
Figure 48
18.15 Hydroblock
•
Read the notes at the head of this section before
commencing any work on the appliance.
•
Remove the secondary heat exchanger as detailed in
18.7
.
•
Remove the pump with the hydroblock section as detailed
in
18.6
.
•
Remove the section of the hydroblock from the pump by
releasing the clip.
Figure 49
•
Release the heat-exchanger outlet pipe nut
and rotate the pipe for ease of removal from the
remaining section of the hydroblock as described
in
18.2
.
•
Disconnect the three way valve stepper motor
electrical connection and remove the stepper motor
by releasing the clip as described in
18.17
•
Release the nut connecting the CH outlet
connection to the hydroblock (
fi
gure 49).
Figure 50
•
Disconnect the DHW sensor as described in
18.1
.
•
Remove the screw securing the remaining section of the hydroblock to the combination
boiler (
fi
gure 50).
•
Fit the replacement hydroblock sections (
fi
gure 51) in reverse order of removal
ensuring all components are assembled correctly. Replace any seals or gaskets as required.