5
205967-01
Green
or Bare
Copper
Green
or Bare
Copper
Green
or Bare
Copper
OPTIONAL WIRING
This fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 100 Watts, 260 Watts of ad-
ditional lighting may be controlled by this sensor.
When determining what a fixture is rated for, do not simply look at the rating on the light bulb in the fixture. Look at
the marking which specifies the maximum bulb wattage for which the fixture is suitable.
Once you have selected the fixtures to be connected and determined their maximum ratings, add these ratings up. For
instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts respectively, you have a total load of 325 Watts.
Wiring Diagram 1 –
When wiring to control a standard light fixture: Strip the motion sensor’s red wire and connect to
the standard light’s black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 2 –
When wiring to control another motion sensing light fixture (Master / Slave): Strip the red wire in
both light fixtures. Connect the red wire of the controlling (master) fixture to the red and black wires of the controlled
(slave) fixture. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 3 –
When wiring so either motion light turns on the both motion lights (Master / Master): Strip the
red wire in both light fixtures. Connect the red wire of one fixture to the red wire of the second fixture.
Note:
In most
installations, an additional wire (same gauge as existing house wire) will have to be installed in the house to connect the
two fixtures as master / master. Connect all white wires together and all black wires together. Total fixture ratings must
not exceed 360 Watts (3.0 A).
Black
White
Light
Fixture
Light
Fixture
(Standard)
Master
Slave
Black
White
Light
Fixture
Light
Fixture
Red
Red
Wiring Diagram 1
Wiring Diagram 2
Wiring Diagram 3
Master
Master
Black
White
Red
Light
Fixture
Light
Fixture