background image

PLUG-IN ROOM TEMPERATURE CONTROLLER

 HEATERMATE 

TM

 

 

Model HY02TP

 

 

Thank  you  for  choosing 

HEATERMATE

.  This  electronic  temperature  controller  will  provide  you  with 

comfortable home environment and will help you to save energy. 

QUICK START-UP GUIDE: 

Plug HEATERMATE into power point 

– a display showing current ROOM temperature and SET temperature 

will come up. By pressing Up or  Down buttons select your desired SET temperature. Plug  your heater into 

Heatermate. If child lock is activated press/hold Down button for 3 seconds then release to unlock. 

BUTTONS EXPLAINED: 

NO. 

Symbols 

Explanation 

 

Power ON/OFF 

 

Short press to switch between Manual and Automatic Modes 

 

Press to Enter/Confirm 

 

Increase (Up) Button 

 

Decrease (Down) Button 

Indicator 

Light is ON -- power to heater is ON; light is OFF -- power to heater is OFF. 

DISPLAY SYMBLES EXPLAINED: 

NO. 

symbols 

Explanation 

 

Automatic control mode (manual control 

“ ” is not showing) 

 

Manual control mode (automatic control 

” is not showing) 

 

Heating mode; “

” is displayed when power to heater is ON   

 

Cooling mode; “

” is displayed when power to air conditioner or fan is ON 

 

 

6 periods programmable icon 

 

Room temperature 

 

Child lock: activated automatically after 10 minutes of inactivity. Press/hold Down button 

for 3 

seconds then release to unlock. Repeat the same procedure to lock. 

10 

 

Ventilation mode 

– turns heater off for a specified period of time during room ventilation (opening 

windows) when room temperature drops below a specified temperature. 

11 

 

Clock setting icon 

DISPLAY OVERVIEW: 

 

 

1) Operation - Heating   

Heatermate  will  turn  your  heater  ON  when  ROOM  temperature  drops  1  degree  below  SET  temperature  and  will  turn  your 

heater OFF when ROOM temperature rises 1 degree above SET temperature. This 2 degrees temperature differential (which 

comes as default) can be increased or reduced based on your preference 

– please refer to Section 6. Smaller differential will 

lead to smaller room temperature fluctuations, but the heater will come ON/OFF more frequently and vice versa. 

 

2) Clock Setting 

Press/hold 

” for 3 seconds then release to enter into setting screen. “

” icon is flashing. Press “

” to enter into clock 

setting mode which displays minute, hour and day of the week. Minute is flashing.

 

P

ress “

” or “ ” to set minutes then press 

” to save and move to hours. Set hours and day of the week in similar manner.   

3) Timer Function   

The Timer function is designed to enable customer to switch Heatermate ON for one fixed time period every day defined by 

ON and OFF times. Outside of this time period Heatermate will be in OFF state (nothing will be showing on its display).

 

 

To set Timer press/hold 

” for 3 seconds then release to enter into setting screen. Press“

”to select “

”(

will flash) 

P

ress “

”  or “ ”  to set  ON  time. Press“

”  to save then  press“

”to select  “

” and set  OFF time. To disable Timer 

function set both ON and OFF times to 00.00 (comes as default). 

Example: Set Timer for heater to come ON at 10pm every night, maintain 21.0 degrees temperature and turn OFF at 7am.   

(i) Set ON time to 22:00 and OFF time to 08:00 by following above steps; (ii) Set the SET temperature to 21.0 degrees C; (iii) 

Turn Heatermate OFF by pressing Power button 

– the display will go OFF. Heatermate will then stay OFF until 10pm, when it 

will come back ON (the display will come up). It will then run until 7am, maintaining room temperature of 21.0 degrees. At 7am 

it will turn itself OFF (the display will go OFF) until 10pm, when it will come back ON, and so on, every day. 

NB

: The Timer ON/OFF times, once set, will apply to both Manual and Automatic Modes 

4) Automatic Mode - Weekly Programming 

Automatic Mode (        symbol is showing next to SET temperature) allows customer to program up to 6 periods with different 

SET temperatures for every weekday and up to 2 periods for the weekend. The table below shows the factory pre-set periods 

and their temperatures. If less than 6 periods per day are required, then the adjacent periods can be merged into one period as 

illustrated in the Example below. When device is in Automatic Mode, the display will always be ON, showing the current period 