18
Twin
Approx.
Flow
Dimensions (In.)
Fan
Ship Wt.
Model
A
B
C
D
E
F
G
H
J
K
L
M Qty. Dia.
(Lbs.)
09
16
1
/
8
19
1
/
8
7
9
/
16
4
2
5
/
16
9
9
/
16
2
3
/
4
4
7
/
8
4
1
/
2
8
5
/
8
2
1
/
2
2
5
/
8
1
5
1
/
2
”
12
13
16
1
/
8
19
1
/
8
7
9
/
16
4
2
5
/
16
9
9
/
16
2
3
/
4
4
7
/
8
4
1
/
2
8
5
/
8
2
1
/
2
2
5
/
8
2
5
1
/
2
”
14
18
16
1
/
8
19
1
/
8
7
9
/
16
4
2
5
/
16
9
9
/
16
2
3
/
4
5
3
/
4
4
1
/
2
8
5
/
8
2
1
/
2
2
5
/
8
1
8”
15
25
18
1
/
8
26
1
/
8
11
1
/
16
4
2
5
/
16
13
1
/
16
2
3
/
4
6
3
/
4
5
1
/
2
12
1
/
8
3
1
/
2
2
5
/
8
2
8”
23
35
18
1
/
8
26
1
/
8
11
1
/
16
4
2
5
/
16
13
1
/
16
2
3
/
4
6
3
/
4
5
1
/
2
12
1
/
8
3
1
/
2
2
5
/
8
2
8”
24
45
21
1
/
8
29
1
/
8
8
3
/
16
7
3
/
4
3
7
/
16
19
5
/
8
3
1
/
2
9
1
/
4
8
13
5
/
8
5
15
/
16
4
1
/
4
2
8”
34
55
21
1
/
8
29
1
/
8
8
3
/
16
7
3
/
4
3
7
/
16
10
5
/
8
3
1
/
2
8
1
/
2
8
13
5
/
8
5
15
/
16
4
1
/
4
1
12”
34
Twin Flow Air Defrost Unit Cooler
Dimensional Diagram
NOMENCLATURE
BTO
K
13
A
G
Twin Coil Motor
Fan
Fan
Motor
Models
115V
208/230V
Blade
Guard
Mount
09
25300701 25300801
5101B
5054D
91179001
13
25300701 25300801
5101B
5054D
91179001
18
25303201 25303301 23100201 H50328
23101401
25
25303201 25303301 23100201 H50328
23101401
35
25303201 25303301 23100201 H50328
23101401
45
25303201 25303301 23100201 H50328
23101401
55
5036S
5036T
5110E
5055F
40003001
Replacement Parts
Expansion Valve Recommendations
25°F. Sat. Suction Temp.
20°F. Sat. Suction Temp.
Model
BTUH @ R-22
BTUH @ R-22
Size
10°F. TD
Alco
Sporlan 15°F. TD
Alco
Sporlan
09
900
1350
13
1300
HF S
1
/
4
HC EFV
1
/
5
C
1950
HFS-
1
/
4
HC EFV-
1
/
5
C
18
1800
2700
25*
2500
3750
35*
3500
5250
45*
4500
6750
55*
5500
8250
HFES-
1
/
4
HC
HFES-
1
/
2
HC
EFVE-
1
/
3
C
EFVE-
1
/
2
C
HFES-
1
/
2
HC
HFES-1
HC
EHFE-
1
/
3
C
EFVE-1
C
Mounting
The Twin Flow unit cooler is
designed for mounting from the
top of the cooler. Drill holes for bolts
or screws according to dimensions
given in Dimensional Diagram and
Data. Double keyhole slots are
provided so screws may be installed
first and then the unit positioned
over the screw head and slid left or
right, then tighten screws to secure
the unit.
FOR FOOD
SERVICE
INSTALLATIONS
. . . seal any joint
between unit cooler
and cooler liner
with a sealant
listed by the
National Sanitation
Foundation,
Standard 51
NOTE: All units have 1/2 I.D. suction, 1/2 O.D. sweat inlet connection and 1/2 O.D. drain.
Vintage
A = 115-1-60
B = 208/230-1-60
Size
K = Coated coil
Twin Flow
Dimensional Data
*Sizes 25, 35, 45 & 55 use external equalized valves.