FOR FOOD 

SERVICE 

INSTALLATIONS

. . .  seal any joint 

between unit cooler 

and cooler liner 

with a sealant 

listed by the 

National Sanitation 

Foundation, 

Standard 51

NOMENCLATURE

LT

  

A

  

053

  

A

  

A

     

 

 

 

Vintage

     
     A = Air Defrost   

 

A = 115-1-60

     L = Electric Defrost 

 

B = 208/230-1-60

 

         Size

Extended Thin Profile Unit Cooler

Dimensional Diagram

Extended

Thin Profile

Unit Cooler

Connections- Electric Defrost

Nozzle Selection- Electric Defrost

  Air 

Electric   Number                                         Dimensions (Inches / mm)

  Defrost  Defrost 

of 

  LTA 

LTL 

Fans  Inches 

mm 

Inches 

mm 

Inches 

mm 

Inches 

mm

  053 

046 

49 3/8 

1254 

40 7/8 

1038 

--- 

--- 

--- 

---

  079 

068 

69 1/8 

1756 

60 5/8 

1540 

--- 

--- 

--- 

---

  102 

093 

88 7/8 

2257 

80 3/8 

2042 

40 7/8 

1038 

--- 

---

  134 

115 

108 5/8  2759  100 1/8  2543 

40 7/8 

1038 

--- 

---

  172 

133 

128 3/8  3261  119 7/8  3045 

40 7/8 

1038 

39 1/2 

1003

 

Number 

Connections (Inches) 

Net

  Model 

of 

Coil 

 

External 

 

Weight

  Size 

Fans 

Inlet 

Suction  Equalizer  Drain 

(Lbs.)

  LTA 053 

1/2 OD  5/8 ID 

1/4 

3/4 MPT 

48

  LTA 079 

1/2 OD   5/8 ID 

1/4 

3/4 MPT 

69

  LTA 102 

1/2 OD  7/8 ID 

1/4 

3/4 MPT 

85

  LTA 134 

1/2 OD  7/8 ID 

1/4 

3/4 MPT 

108

  LTA 172 

1/2 OD  1 1/8 ID 

1/4 

3/4 MPT 

124

 

Number 

Connections (Inches) 

Net

  Model 

of 

Coil 

 

External 

 

Weight

  Size 

Fans 

Inlet 

Suction  Equalizer  Drain 

(Lbs.)

  LTL 046 

1/2 OD  5/8 ID 

1/4 

3/4 MPT 

48

  LTL 068 

1/2 OD  5/8 ID 

1/4 

3/4 MPT 

69

  LTL 093 

1/2 OD  7/8 ID 

1/4 

3/4 MPT 

85

  LTL 115 

1/2 OD  7/8 ID 

1/4 

3/4 MPT 

108

  LTL 133 

1/2 OD  1 1/8 ID 

1/4 

3/4 MPT 

124

 Number  Air  Distributor Tube Number

  of 

Defrost  OD  Length 

of

  Fans 

LTA  (Inches) (Inches) Circuits  R404A  R22

 

053 

3/16  21 1/2 

L-1/2  L-1/3

 

079 

3/16  21 1/2 

L-1/2  L-1/3

 

102 

3/16  21 1/2 

L-3/4  L-1/2

 

134 

3/16  21 1/2 

L-1 

L-3/4

 

172 

3/16  21 1/2 

L-1 1/2  L-1

  Number Electric Distributor Tube Number  Low Temp. 

Medium Temp.

  of 

Defrost  OD  Length 

of 

-30ºF to 0ºF SST  +10ºF to +25ºF SST

  Fans 

LTL  (Inches) (Inches) Circuits  R404A  R22  R404A  R22

   2 

046 

3/16  21 1/2 

L-3/4  L-1/2 

L-1/2 

L-1/3

 

068 

3/16  21 1/2 

L-3/4  L-1/2 

L-3/4 

L-1/2

 

093 

3/16  21 1/2 

L-1 

L-3/4 

L-1 

L-3/4

 

115 

3/16  21 1/2 

L-1 1/2  L-1 

L-1 

L-3/4

   6 

133 

3/16  21 1/2 

L-1 1/2  L-1 

L-1 1/2 

L-1

Dimensional Data

Connections- Air Defrost

Nozzle Selection- Air Defrost

Summary of Contents for 25005601

Page 1: ...Replacement Parts 5 Electric Defrost Troubleshooting 5 Thin Pro le Air Defrost Unit Cooler 6 Thin Pro le Electric Defrost Unit Cooler 7 9 Extended Thin Pro le Unit Cooler 10 11 V Pro le Unit Cooler 1...

Page 2: ...2...

Page 3: ...3 2005 Heatcraft Refrigeration Products LLC...

Page 4: ...revent freeze up If only a small portion of the drain line is located in the refrigerated area a drain line heater will not be required If a drain line heater is required use approximately 15 watts pe...

Page 5: ...ad remove motor leads from terminal block and apply correct voltage across the leads If motor still does not operate satisfactorily it must be replaced Before starting the unit rotate fan blades to ma...

Page 6: ...3 8 9 1 2 15 16 4 3 8 20 1 2 3 8 OD 3 8 ID 1 2 OD 17 17 22 1 8 15 15 16 14 1 2 11 1 8 12 4 1 2 9 3 8 11 1 4 15 16 4 3 8 24 3 8 OD 1 2 ID 1 2 OD 21 23 29 3 4 15 15 16 14 1 2 13 20 7 8 4 1 2 10 3 4 10...

Page 7: ...ead and cabinet and secure in place Install the front mounting screws For proper drainage the unit should be installed level Thin Pro le Vintage Electric Defrost Size A 115 1 60 B 208 230 1 60 NOMENCL...

Page 8: ...F Step C Coil Re Cooling Cycle 1 When the coil warms up to 55 F the defrost termination thermostat closes which allows the current to ow to the solenoid in the timer which then energizes and trips th...

Page 9: ...9 Typical System Wiring Diagram with Thin Pro le Electric Defrost Unit Cooler...

Page 10: ...102 4 1 2 OD 7 8 ID 1 4 3 4 MPT 85 LTA 134 5 1 2 OD 7 8 ID 1 4 3 4 MPT 108 LTA 172 6 1 2 OD 1 1 8 ID 1 4 3 4 MPT 124 Number Connections Inches Net Model of Coil External Weight Size Fans Inlet Suctio...

Page 11: ...30V 208 230 1 60 5 24723006 Defrost Heater 3300W 230V 208 230 1 60 6 23305501 Heater Clip N A 3 7 Part Description 25315501 Motor 115 1 60 Shaded Pole 25315601 Motor 208 230 1 60 Shaded Pole 22919001...

Page 12: ...ndations V 25 F Evaporating Temp 20 F Evaporating Temp Pro le BTUH R 22 BTUH R 22 Model 10 F TD Alco Sporlan 15 F TD Alco Sporlan 06 600 900 08 800 HFS1 4 HC EFV1 5 C 1200 HFS1 4 HC EFV1 5 C 12 1200 1...

Page 13: ...crews through top front mounting holes to ceiling of box Expansion Valve Recommendations 25 F Sat Suction Temp 20 F Sat Suction Temp Model BTUH R 22 BTUH R 22 Size 10 F TD Alco Sporlan 15 F TD Alco Sp...

Page 14: ...R 22 Size 10 F TD Alco Sporlan 15 F TD Alco Sporlan 13 1300 1950 17 1700 HFS 1 4HC EFV 1 5C 2550 HFS 1 4HC 23 2300 3450 Expansion Valve Recommendations Replacement Parts Part Standard Reverse Descrip...

Page 15: ...241 2 24 413 16 85 8 231 8 20 M16 1 600 180 2 1 150 261 4 255 8 241 2 24 413 16 85 8 231 8 19 Low 10 F Sat Suction Temp 15 F Sat Suction Temp Temp BTUH R 404A BTUH R 404A Model 10 F TD Alco Sporlan 15...

Page 16: ...16 Air Defrost Wiring Model BBM Electric Defrost Wiring Model BBL...

Page 17: ...BTUH R 22 Size 10 F TD Alco Sporlan 15 F TD Alco Sporlan 009 850 1275 012 1150 HFS 1 4HC EFV 1 5C 1725 HFS 1 4HC EFV 1 5C 015 1500 2250 NOMENCLATURE U K 009 0 B U Dual Aire K Coated Coil Size Design R...

Page 18: ...5303201 25303301 23100201 H50328 23101401 55 5036S 5036T 5110E 5055F 40003001 Replacement Parts Expansion Valve Recommendations 25 F Sat Suction Temp 20 F Sat Suction Temp Model BTUH R 22 BTUH R 22 Si...

Page 19: ...19...

Page 20: ...is a continuing effort we reserve the right to make changes in speci cations without notice Heatcraft Refrigeration Products LLC 2175 W Park Place Blvd Stone Mountain GA 30087 770 465 5600 Fax 770 465...

Reviews: