4
SPECIFICATIONS
Model No. S1505
Designed to ANSI Z83.7-1991
Construction Heater
Gases:
Natural or Propane
Capacity:
1,500,000 Btu/h maximum
850,000 Btu/h minimum
Orifice Size:
41 DMS (x46)
Blower:
7,000 CFM
Electrical Rating:
115V, 60Hz, 20 amps, single phase
Min. Temperature Rating
-40ºF
Gas Supply:
Inlet Pressure
Manifold Pressure
Max W.C.
Min W.C.
Max W.C.
Min W.C.
Propane
14”
9”
2.7”
.75”
Natural Gas
14”
9”
7.2”
2.0”
(Minimum inlet pressure is for purpose of input adjustment)
DESIGN RELATED ADDITIONAL SAFETY FEATURES
1.
Locking position for LPG on gas selector lever:
Units used with LPG while the gas
selector valve is positioned for Natural Gas will throw significantly more heat than
the rated Btu/h. This is definitely a safety hazard.
2.
Low skin temperature:
Sure Flame Heaters are designed to have a low skin
temperature. This provides added safety in the workplace.
3.
Durable Construction:
The Model S1505 used a stainless steel burner for long life
and consistent performance.
In order to maintain the highly efficient combustion of the Sure Flame Heater, the com-
bustion chamber must remain as manufactured. Any change or distortion could alter the
fuel/air mixture and create unwanted gases.