background image

1

- Do not store or  use gasoline or other flam-

mable vapors and liquids in the vicinity of this
or any other appliance.

-

What to do if you smell gas

• Do not try to light any appliance.

• Do not touch any electrical switch.

• Do not use any phone in your building.

• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's
instructions.

• If you cannot reach your gas supplier, call

the fire department.

- Installation and service must be performed by a

qualified installer, service agency, or the gas
supplier.

Model:

Grand-50-D

Installers Guide

WARNING: IMPROPER INSTALLA-
TION,  ADJUSTMENT,  ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT  A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.

Underwriters

Laboratories Listed

570-900G   8/02

READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS 

INSTALLERS

GUIDE 

MUST BE LEFT WITH APPLIANCE FOR

FUTURE REFERENCE.

Please contact your Heat-N-Glo dealer with any
questions or concerns. For the number of your nearest
Heat-N-Glo dealer, please call 1-888-427-3973.

Printed in U.S.A.   Copyright 2002,

Heat-N-Glo, a division of Hearth Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044

WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.

This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.

1. This appliance may be installed in an af-

termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.

2. This appliance is only for use with the type

of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.

Summary of Contents for Grand-50-D

Page 1: ...IANCE FOR FUTURE REFERENCE Please contact your Heat N Glo dealer with any questionsorconcerns Forthenumberofyournearest Heat N Glo dealer please call 1 888 427 3973 Printed in U S A Copyright 2002 Hea...

Page 2: ...DERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the firs...

Page 3: ...Approvals 11 B Installing Vent Components 15 C Vent Termination 17 Step 4 Positioning Leveling and Securing the Fireplace 20 Step 5 The Gas Control Systems 20 Step 6 The Gas Supply Line 21 Step 7 Gas...

Page 4: ...22 1 Canadian Electric Code in Canada These models may be installed in a bedroom or bed sitting room in the U S A and Canada Approvals and Codes High Altitude Installations U L Listed gas fireplaces a...

Page 5: ...ilure to follow these instructions will void the owner s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the following...

Page 6: ...AL ACCESS VENT COLLARS 34 864mm 17 432mm 25 1 8 638mm 16 5 8 421mm 47 1 4 1200mm 44 1 8 1121mm 50 5 8 1286mm 56 1 2 1435mm 7 1 8 181mm 2 3 4 70mm GAS LINE ACCESS HOOD TOP STANDOFFS ELECTRICAL ACCESS G...

Page 7: ...inimum clearances of direct vent termination see Fig ures 19 and 20 Step 2 Framing the Fireplace Fireplace framing can be built before or after the fireplace is set in place Framing should be position...

Page 8: ...AP 1 3 8 INCHES 34 93 mm AT EACH JOINT DV 36D 5 3 4 146mm 8 3 4 222mm 11 3 4 298mm DV 12D DV 09D DV 06D DV 48D DV 90D 7 3 8 187mm 6 5 32 156mm 11 5 8 295mm 11 15 16 303mm 5 7 8 149mm 8 5 8 220mm 8 1 2...

Page 9: ...erappearancemayvarybasedonthetype of fuel burned and the venting configuration used Termination Kits WARNING A 3 FOOT LENGTH OF STRAIGHT PIPE MINIMUM MUST BE THE FIRST VENT COMPONENT ATTACHED TO THE U...

Page 10: ...WITH ONE 1 90 ELBOW V FT H FT 3 MIN 914 mm 6 MAX 1 9m 4 MIN 1 2m 8 MAX 2 4m 5 MIN 1 6m 10 MAX 3 1m 6 MIN 1 9m 12 MAX 3 6m V H 30 MAX 9 3 m Ratio V to H 1 2 Figure 7 Venting with One 90 Elbow H 20 MAX...

Page 11: ...io V to H H1 1 2 Figure 8 Venting with two 90 elbows VENTING WITH TWO 2 90 ELBOWS V FT H FT 3 MIN 914 mm 6 MAX 1 9m 4 MIN 1 2m 8 MAX 2 4m 5 MIN 1 6m 10 MAX 3 1m 6 MIN 1 9m 12 MAX 3 6m V V1 H1 30 MAX 9...

Page 12: ...MAXIMUM 9 3m H H1 20 MAXIMUM 6 2m H 10 MAXIMUM 3 1m VENTING WITH THREE 3 90 ELBOWS V FT H H1 FT 3 MINIMUM 914 mm 6 MAXIMUM 1 9 m 4 MINIMUM 1 2 m 8 MAXIMUM 2 4 m 5 MINIMUM 1 6 m 10 MAXIMUM 3 1 m 6 MIN...

Page 13: ...locked position with the pre ceding component attach with a minimum of two 2 sheet metal screws Figure 11 Adding Venting Components 3 Install Support Brackets For Horizontal Runs The vent system must...

Page 14: ...G NEW FRAMING MEMBERS EXISTING CEILING JOISTS CHIMNEY HOLE 11 280 mm 11 280mm For Vertical Runs One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes To install fi...

Page 15: ...LEARANCES Figure 19 Round Trapezoid Termination Caps ROUND CAP TERMINATION PERFORATION CANNOT BE INSIDE THE WALL 7 1 2 191mm MINIMUM TRAPEZOID CAP TERMINATION 7 1 4 184mm Figure 17 Ceiling Firestop Ce...

Page 16: ...PS IT IS STRONGLY RECOMMENDED WHENEVER POSSIBLE TO USE THE VINYL PROTECTOR KIT 5 foot minimum for vinyl clad soffits a vent shall not terminate directly above a sidewalk or paved driveway which is loc...

Page 17: ...OVIDED THE TERMI NATION CAP IS AT LEAST TWO 2 FEET FROM A VERTICAL WALLAND 2 FEET BELOW AHORIZON TAL OVERHANG NOTE This also pertains to vertical vent systems in stalled on the outside of the building...

Page 18: ...gure 23 Proper Positioning Leveling and Securing of a Fireplace Figure 24 Gas Control System Step 5 The Gas Control System WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL Intermittent Pilot Ignition...

Page 19: ...ied installer approved and or licensed as required by the locality In the state of Massachusetts installation must be performed by a licensed plumber or gas fitter NOTE Before the first firing of the...

Page 20: ...y cutting and removing cable tie Plug transformer into electric box terminal marked fan Check that antenna wire is held in place by two clips on the lower flange see Figure 35 Optional Fan Kits Fan ki...

Page 21: ...SEALANT MATE RIAL MUST BE USED THESE JOINTS ARE NOT RE QUIRED TO BE SEALED ONLY NON COMBUSTIBLE MATERIAL USING 300 F MINIMUM ADHESIVE IF NEEDED CAN BE APPLIED AS FACING TO THE FIRE PLACE SURROUND SEE...

Page 22: ...the top of the burner near front and center ports with a single layer of ember material Sprinkle GE 93 on top of the burner Save the remaining ember materials for use during fire place servicing Use o...

Page 23: ...sembly GLASS CLIPS Step 11 Before Lighting the Fireplace BEFORE lighting the fireplace be sure to do the following Remove all paperwork from underneath the fireplace Review all cautions and Safety and...