TR3100 Thermos t at I nstructions
See overleaf for further setting up information
This thermostat is a combination model allowing you to
choose between 3 different models. A, AF and F model.
A model: air onl y , with built in sensor
AF model: air & floo r , with both built in and remote sensor
F model: floor onl y , with remote sensor
General Settings
Press buttton t o T urn on/o f f the thermostat. When thermostat is turn ed off, the LCD will only display current temperature reading. When the thermostat is
turned off, press and hold button M for 3 seconds to bring up a configuration menu. In this mode, press button M to select different features’ setting.
( P art I)
Menu #
1
Model (model selection)
Sd (switching differential)
ATC (air temp calibrate)
FTC (floor temp calibrate)
TR--AF (AF model only)
(TR= Temperature readout )
MAXFT (set maximum floor
temp in AF model)
BL (backlight turning-on time
setting)
TF (temperature format)
CLOCK
24 (default), 12- hour or 24-hour clock system
PTD (program time delay)
2
3
4
5
6
7
8
9
10
11
12
Features description
Features Explanation
Adjustment
1 = 1 degree(default), 2 =2 degrees.........
-1 = decrease 1 degree, 1 = increase 1 degree...
5s , 10s , 15s ,20s (default) , 25s, 30s.
A= to show air temperature, F=to show floor temperature,
A--F = to show both in 5 second intervals
40 degree(default)
30 seconds(default) On= always on, OFF= always off
C or F
A, AF, F
(press up or down button to adjust)
-1 = decrease 1 degree, 1 = increase 1 degree...
This product should be installed by a qualified electrician.
If the floor sensor is short-circuit or broken, the LCD will display “Err” an d t he thermostat will cut o f f output.
Please Note: one of the following error messages will appear if one of these problems occur:
The numbers of degree difference before switching.
The default is 1°C which means the thermostat will
switch the heating on 0.5°C below the set temperature
and will turn it off 0.5°C above the set temperature.
With a 2°C differential, the heating will switch on 1°C
below the set temperature and will switch off 1°C
above the set temperature.
This is to calibrate air temperature if required.
This is to calibrate floor temperature if required.
This gives more time for user to set the programmes
before reverting back to standard display
This gives option to choose to show air temperature,
floor temperature or to show both floor & air in interval.
This is to protect the floor surface.
This is to set the backlight turning-on time. User
can also set the backlight always on or off.
This alows users to select between °C or °F.
12/24 HOUR clock system selection
Buttons and LCD display
Button / Icon
Description
Turning on/off thermostat
Menu button / Program button
Auto/Manual mode selection
Increase the set value
Decrease the set value
Set the time and week days
M
The buttons are locked.
Heating is turned on
Button / Icon Description
Auto mode(select by button M)
Manual mode(select by button M)
Vacation mode
Temporary temperature override
Frost protection activated
Set temperature
Programmes number
Room temperature
RT
AUTO
SET
Floor temperature
Economy temperature
Comfort temperature
FT
The difference between set
temperature and room temperature
more bars means more difference
override
SC(setpoint configuration)
“2” means: set temperature in program 1 equals the set temperature in
“4” means the 4 programmes will have 4 independent set temperatures.
Each set temperature can be different to the others.
program 3 ; set temperature in program 2 equals the set temperature in
program 4 ; If set temp in program 1 is changed, set temp in program 3
temp in program 2 is changed, set temp in program 4 will be changed
will be changed automatically to the same set temp as program 1. If set
automatically to the same set temp as program 2.
This allows user to select between 2 sets of default
programmed setpoints.
FP(Frost protection)
on= activated, off= deactivated
This is to avoid room temperature goes below 5°C
Ver.1.3
Optional Remote Controller
(TR3100RC model only)
Turn on/off thermostat
Lock or unlock buttons
Menu(in OFF mode)
Confirm setting
Vacation mode
Program button
Set day
Set time
View floor temp
(AF model only)
Cancel Override
Auto/Manual selection
Increase the set value
Decrease the set value
Prog
Time
Day
Auto
Manu
Prog
Menu
Enter
Time
Day
Auto
Floor
Temp
Run
Schl