TR3100    Thermos t at   I nstructions 

See overleaf for further setting up information 

This thermostat is a combination model allowing you to  

choose between 3 different models. A, AF and F model. 

A  model:      air onl y , with built in sensor 

AF model:   air & floo r , with both built in and remote sensor 

F model:      floor onl y , with remote sensor 

General Settings

Press  buttton             t o   T urn on/o f f the thermostat. When thermostat is turn ed off, the LCD will only display current temperature reading. When the thermostat is   

turned off, press and hold button M for 3 seconds to bring up a configuration menu. In this mode, press button M to select different features’ setting. 

( P art I) 

Menu #

 1

Model (model selection) 

Sd (switching differential) 

  ATC (air temp calibrate) 
  FTC (floor temp calibrate) 

TR--AF    (AF model only)

(TR= Temperature readout  ) 

MAXFT (set maximum floor

 temp in AF model) 

BL (backlight turning-on time 

setting) 

TF (temperature format) 

CLOCK 

24 (default),  12- hour or 24-hour clock system

PTD (program time delay) 

2

3

4

5

6

7

8

9

10

11

12

Features description 

Features Explanation 

Adjustment 

1 = 1 degree(default),  2 =2    degrees.........

-1 = decrease 1 degree,  1 =  increase 1 degree...

  5s  ,  10s   , 15s   ,20s (default) , 25s, 30s.

A= to show air temperature,  F=to show floor temperature,

  A--F = to show both in 5 second intervals 

  40 degree(default)

   30 seconds(default)  On= always on, OFF= always off

  C  or    F

A, AF, F

(press up or down button to adjust)

-1 = decrease 1 degree,  1 =  increase 1 degree...

This product should be installed by a qualified electrician. 

If the floor sensor is short-circuit or broken, the LCD will display “Err” an d t he thermostat will cut o f f output. 

Please Note: one of the following error messages will appear if one of these problems occur: 

The numbers of degree difference before switching.  

The default is 1°C which means the thermostat will  

switch the heating on 0.5°C below the set temperature  

and will turn it off 0.5°C above the set temperature.  

With a 2°C differential, the heating will switch on 1°C 

below the set temperature and will switch off 1°C 

above the set temperature.   

This is to calibrate air temperature if required. 
This is to calibrate floor temperature if required. 

This gives more time for user to set the programmes 

before reverting back to standard display 

This gives option to choose to show air temperature, 

floor temperature or to show both floor & air in interval. 

This is to protect the floor surface. 

This is to set the backlight turning-on time. User  

can also set the backlight always on or off. 

This alows users to select between °C or °F.  

12/24 HOUR clock system selection 

Buttons and LCD display

Button / Icon 

Description

Turning on/off thermostat

Menu button /  Program button

Auto/Manual mode selection

Increase the set value

Decrease the set value

Set the time and week days

M

The buttons are locked.

Heating is turned on

Button / Icon  Description

Auto mode(select by button M)

Manual mode(select by button M)

Vacation mode

Temporary temperature override

Frost protection activated

Set temperature
Programmes number
Room temperature

RT

AUTO

SET

Floor temperature

Economy temperature

Comfort temperature

FT

The difference between set 
temperature and room temperature 

more bars means more difference

override

SC(setpoint configuration)

“2” means: set temperature in program 1 equals the set temperature in

“4” means the 4 programmes will have 4 independent set temperatures.

Each set temperature can be different to the others.

program 3 ; set temperature in program 2 equals the set temperature in

program 4 ; If set temp in program 1 is changed, set temp in program 3

temp in program 2 is changed, set temp in program 4 will be changed 

will be changed automatically to the same set temp as program 1. If set

automatically to the same set temp as program 2. 

This allows user to select between 2 sets of default 

programmed setpoints.

FP(Frost protection)

on= activated,  off= deactivated

This is to avoid room temperature goes below 5°C 

Ver.1.3 

Optional Remote Controller

  (TR3100RC model only)

Turn on/off thermostat

Lock or unlock buttons

   Menu(in OFF mode)

Confirm setting

Vacation mode

Program button

Set day

Set time

View floor temp

(AF model only)

Cancel Override

Auto/Manual selection

Increase the set value

Decrease the set value

Prog

Time

Day

Auto

Manu

Prog

Menu

Enter

Time

Day

Auto

Floor 

 Temp

Run

Schl