Heat Controller 7602-443 User Manual Download Page 1

Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com

USER MANUAL

7602-443 Communicating,

Programmable Thermostat

Summary of Contents for 7602-443

Page 1: ...Heat Controller Inc 1900 Wellworth Ave Jackson MI 49203 517 787 2100 www heatcontroller com USER MANUAL 7602 443 Communicating Programmable Thermostat...

Page 2: ...ustment 4 3 0 Fan Mode Selection 4 4 0 Humidity Level Adjustment 5 5 0 Main Menu Options Overview 6 5 1 Date and Time 7 5 2 Hold 7 5 3 Program 9 5 4 Fan 9 5 5 Mode 9 5 6 Other Settings 10 5 7 Security...

Page 3: ...AUTO HUMID ON AUTO SETPOINT HEAT 62 COOL 82 RH TEMP FAN MENU MODE AUTO OPERATING MODE MENU SAVE OFF COOL HEAT EMERGENCY PREVIOUS CHANGE MODE HEAT The 7602 443 Communicating Programmable Thermostat is...

Page 4: ...the Heating setpoint may be automatically reduced to enforce a 2 F dead band NOTE 3 In programmable mode the TEMP option provides the ability to temporarily modify setpoint s until the start time of...

Page 5: ...ints Adjust the setpoints using the up down arrow buttons Press the center button to save changes Humidification Setpoint default 40 options 10 to 45 in 5 increments NOTE Humidifier must be installed...

Page 6: ...ER HOUR 5 6 4 AUTO CHANGEOVER TIME 5 6 5 PROGRAM SETTINGS 5 6 5 1 Smart Recovery 5 6 5 2 Events Per Day 5 6 5 3 Smart Heat Staging 5 6 5 4 Electric Heat Lockout 5 6 5 5 Demand Reduction 5 6 6 INTERMIT...

Page 7: ...y adjusts the time for daylight savings time 5 1 2 SET DATE AND TIME To set the current date and time use the up down arrow buttons Press the center button to save changes 5 1 3 DISPLAY DATE AND TIME...

Page 8: ...Minimum Cooling Setpoint Limit section 5 6 8 95 F NOTE The thermostat forces a 2 F dead band between the Heating and Cooling setpoints While adjusting the Heating setpoint the Cooling setpoint may be...

Page 9: ...ividual days or schedules for groups of days Event Heat Cool Fan see NOTE 2 Day 6 00A 70 F 78 F Auto Night 10 00P 62 F 82 F Auto SELECT OPTION MONDAY PREVIOUS TUESDAY WEDNESDAY COPY THURSDAY SATURDAY...

Page 10: ...art Recovery 5 6 5 2 EVENTS PER DAY NOTE The thermostat must be configured for programmable mode by installer to access the Events per Day setting Events Per Day sets the number of program schedule ev...

Page 11: ...uction schedule DEMAND REDUCTION OPTION FOR PROGRAM OPERATION SAVE NO AUXILIARY HEAT NO 2ND STAGE COMP PREVIOUS SELECT OPTION NO DEMAND REDUCTION No Demand Reduction default During the scheduled Progr...

Page 12: ...d time settings using the up down arrow buttons in increments of 10 minutes Press the center button to save changes NOTE To disable Programmed Demand Reduction set the Start time equal to the End time...

Page 13: ...igned Demand Reduction input is active the compressor is limited to only part load 1st stage operation and auxiliary heat is turned off regardless of system demand No Operation default if either setti...

Page 14: ...T SETBACK Under Night Setback mode the thermostat will operate using alternate Night Setback heating and cooling setpoints fan mode and humidification and dehumidification setpoints Night Setback is a...

Page 15: ...ttons Press the center button to save changes Auto Operation Only default While the Night Setback input is active the fan output will not be activated unless Y1 or W is active Fan Same As Occupied Whi...

Page 16: ...Date Page Description 17 Sept 12 All First Published Revision History 9 17 12 97B0055N08 97B0055N08...