9
Heat & Glo • Grand-I35-C, Grand-I35-SP, Supreme-I30-C, Supreme-I30-SP • 2206-901 Rev. P • 6/14
I. Before Lighting Fireplace
Before operating this
fi
replace for the
fi
rst time,
have a
quali
fi
ed technician
:
• Verify all shipping materials have been removed from
inside and/or underneath the
fi
rebox.
• Review proper placement of logs, ember material and/
or other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire/Asphyxiation! DO NOT
oper-
ate
fi
replace with
fi
xed glass assembly removed.
Determine if this
fi
replace has a standing pilot or an
Intelli
fi
re ignition system. Ask your dealer or open control
access panel, look at gas valve.
• A standing pilot ignition will have a red or black ignitor
button (refer to Figure 2.4).
• An Intelli
fi
re ignition system will not have a button.
Figure 2.4 Ignitor Button
RED OR BLACK IGNITOR BUTTON
Figure 2.3 Control Module
5.
Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into lock-out
mode by emitting three audible beeps, then continuously
displaying a RED/GREEN error code at its status
indicator LED.
• Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section G.
• Locate the module selector switch. (See Figure 2.3).
• Set the module selector switch to the OFF position.
• Wait
fi
ve (5) minutes to allow possible accumulated gas
to clear.
• Set the module selector switch to ON or REMOTE
position.
• Start the appliance.
WARNING! Risk of Explosion! DO NOT
press the mod-
ule reset switch more than one time within a
fi
ve minute
time period. Gas may accumulate in
fi
rebox. Call a quali-
fi
ed service technician.
4. If you intend to use both an optional wired wall switch
and the RC300 remote control to operate your
fi
replace,
the wall switch will override any commands given by
the remote.
Nine Hour Safety Shutdown Feature
The appliance has a safety feature that automatically
shuts down the
fi
replace after nine hours of continuous
operation without receiving a command from the wall
switch or optional remote.
NG/LP GAS-TYPE
SELECTOR SWITCH
SELECTOR
SWITCH
FLAME HI/LOW
SWITCH
STATUS
INDICATOR LED
MODULE