® Green Mountain Insert 70 (Model 8450)
9
accommodate the insert’s chimney liner,
provided that their removal will not weaken the
structure of the fireplace and chimney, and will
not reduce protection for combustible materials
to less than that required by the building code.
CHIMNEY CAPS:
Mesh type chimney caps must have
provision for regular cleaning, or the mesh
should be removed to eliminate the
potential of plugging.
CLEARANCE TO COMBUSTIBLES:
The fireplace should be inspected to make
sure that there is adequate clearance to
combustibles, both exposed combustibles
to the top, side, and front as well as
concealed combustibles, in the chimney
and mantle area. Your local inspector
should have information on whether older
fireplaces are of adequate construction.
OPENING SIZE:
Refer to page 13
Minimum Masonry
Opening
for
suitable
size
fireplace
openings.
C
ERTIFICATION
L
ABEL
The label is on a metal plaque in the blower space
below the firebox. It is attached with a lanyard to the
firebox so it can pull out far enough for inspection.
Take care when lifting and installing the insert to
keep the label inside the firebox to avoid any
damage.
Figure 2 - Label Location
Since the information given on the certification label
attached to the appliance always overrides the
information published in any other media, it is
important to refer to it to have a safe and compliant
installation. The model and the serial number can
also be found on the label.
It is recommended to note the insert serial number
on this manual. It will be needed to identify the
version of the appliance in the event replacement
parts or technical assistance is required. It is also
recommended to register the warranty online at
www.hearthstonestoves.com
M
ASONRY
F
IREPLACE
T
HROAT DAMPER
If the fireplace's draft control system is to remain in
the masonry fireplace, it must be locked open for
access of the chimney liner or removed entirely. If
you remove draft control system from the masonry
hearth, you will need to install the metal plate
(27009), supplied with the owner’s manual kit,
indicating that the masonry hearth has been
modified. It must be secured inside the masonry
hearth, in a visible place and easy to locate.