Your WFP-75 ships with the facade installed on the front of the firebox. It is recommended that the facade be
removed during installation of the fireplace to avoid damage to the facade and lighten the fireplace. Follow
these instructions to remove and re-install the facade:
1. Open the blower door. It is held
closed by a magnet on the right side
of the frame. Two cables support the
door in the open position.
2. Remove the two screws that secure
the facade frame to the firebox. The
close the blower door.
3. Pivot the facade forward at the top edge and
detach the 2 springs from the holes in the facade
frame.
4. Carefully lift the frame off of the fireplace,
avoiding the door handle.
5. Follow the steps in reverse order to install the
facade.
6. If you are planning to install a non-combustible
facing material behind the facade, plan the depth
of this material before securing the screws. The
facade can be positioned to allow a facing
material thickness between 3/8in (MINIMUM)
and 1in (MAXIMUM).
Note that a non-combustible shim may be added
to the outside of the facade frame if necessary to
center the facade.