10
Clearances To Combustibles
Use this section to plan the layout for your stove.
Consider clearance of connector, and chimney pipe
to combustibles and stove to combustibles. More
specifics on installation follow.
You must follow minimum clearances for the
Mansfield stove to combustibles such as walls and
ceilings. You may reduce the general clearances if
installing the stove near
Protected Surfaces
(see the
following diagrams and the table on page 11).
Figure 5
Figure 6
Figure 7
Figure 8
If you use a rear heat shield to obtain reduced
clearances, you must use the optional rear heat
shield manufactured by Hearthstone available
through
your
local
dealer.
Close
clearance
connector pipe must be tested to UL standards and
listed. Check listings of your pipe for actual
clearances. Shown are measurements typical only
and specific to Simpson Dura Vent DVL brand.
Clearances cannot be reduced without the use of
the rear heat shield and/or with close clearance
connector pipe and/or by protecting the surfaces per
NFPA 211 standards