1
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP-AU) Instructions • 4052-902 Rev. C • 10/19
PVLP-SLP-AU
Power Vent Low Profile
- Installation Instructions -
INTRODUCTION
The Power Vent Low Profile (PVLP-SLP-AU) is certified
for use as a horizontal termination cap only on appliances
manufactured by Hearth & Home Technologies with IPI (in-
termittent pilot ignition) gas controls. Appliances equipped
with millivolt type gas controls CANNOT use this product.
1
Introduction
DO NOT DISCARD THIS MANUAL
NOTICE
• Leave this manual with party
responsible for use and op-
eration.
• Important operating
and maintenance
instructions included.
• Read, understand and follow
these instructions for safe
installation and operation.
Table of Contents
A. Components and Service Parts List . . . . . . . . . . . . . . . . . .
B. Installation of PVLP-SLP-AU. . . . . . . . . . . . . . . . . . . . . . . .
2
2 Vent Information and Diagrams
A. Installation of Vent Pipe. . . . . . . . . . . . . . . . . . . . . . . . . . . .
B. Vent/Pipe Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C. Acceptable Vent Configurations . . . . . . . . . . . . . . . . . . . . .
D. Setting the PVLP-SLP-AU Baffle Adjustment . . . . . . . . . . .
8
A. Framing and Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . .
. Termination Cap Clearances . . . . . . . . . . . . . . . . . . . . . . .
11
C. Installing Vent Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
A. Wiring the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. Wall Switch and Timer Control Junction Box Installation .
C. Time Delay Relay Settings . . . . . . . . . . . . . . . . . . . . . . . .
18
A. Installation Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
. Power Vent Operating Instructions . . . . . . . . . . . . . . . . . .
19
C. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
D. Replace Fan/Pressure Switch. . . . . . . . . . . . . . . . . . . . . .
20
. PVLP-SLP-AU Troubleshooting . . . . . . . . . . . . . . . . . . . .
22
IMPORTANT:
Failure to read and follow these instruc-
tions may create a possible hazard and will void the ap-
pliance warranty.
These instructions must remain with the equipment.
CAUTION! Risk of Cuts or Abrasions.
Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
Installation of the PVLP-SLP-AU may be done by a quali-
fied service technician only. Installation MUST comply
with local, regional, state and national codes and regula-
tions.
AS/NZS 5263.1.3
Suitable for models under coverage
of certificates GMK10222, GMK10477,
GMK10486, GMK10489 and GMK10616
DO NO
T
DISCARD