D. Venting Systems
Chimney Connector:
It is also known as flue pipe or stove pipe. It must be 152mm
minimum diameter stainless steel connector pipe. (Solid or
Flex and must run the entire chimney)
Chimney:
The chimney can be new or existing, masonry or
prefabricated and must meet the following minimum
requirements as specified below.
E. Inspections
Existing chimneys should be inspected and cleaned by a
qualified professional prior to installation. The chimney
must not have cracks, loose mortar or other signs of
deterioration and blockage. Hearth & Home recommends a
certified professional or a technician, under the direction of
a certified professional.
F. Larger Chimneys
Per Australian Standard, all fireplace inserts being installed
into an existing masonry fireplaces require a full 152 (6”)
liner
NOTICE:
Check with your local building authorities.
Risk of Fire!
Follow venting manufacturer’s clearances
and instructions when installing venting
system.
WARNING
!
Fire Risk.
Inspection of Chimney:
•
Chimney must be in good condition.
•
Factory-built chimney must be 152mm.
WARNING
!