i
Information
Please allow up to 40 minutes for the surface to reach
the maximum temperature.
Once flashing temperature has stopped, the indicator
displays the actual temperature measured at the core
of the Mat.
Press and hold
or to reach desired numbers faster.
Default PEMF frequency is set to 7.83 Hz and displayed
as 8 Hz.
FACTORY RESET
WITH THE CONTROLLER ON
The controller will shut
downand turn back ON
automatically
Press and
Hold for 10 sec
To turn PEMF OFF
PEMF
Press and Hold for 6 sec
Press PEMF button once to turn PEMF ON. Press PEMF again to initiate
PEMF frequency adjustment mode (PEMF indicator will start flashing).
Set the desired frequency (1-30 Hz) and press PEMF button again to save
the setting.
PEMF
SET and ADJUST
PEMF
PEMF
PEMF
TIME
TIME
TIMER
SET and ADJUST
Press TIME button to initiate time adjustment mode (time indicator
will start flashing). Set the desired time and press TIME button again to
save the setting.
To switch between
Fahrenheit and Celsius
TIME
Press and
Hold for 6 sec
°
F
or °
C
UNITS SET
TEMP
TEMP
TEMP
TEMPERATURE
SET and ADJUST
Press TEMP button once to turn Heat ON. Press TEMP again to initiate
temperature adjustment mode (temperature indicator will start flashing).
Set the desired temperature and press TEMP again to save the setting.
POWER
Press the Power button to turn ON the controller.
TEMP, TIMER, PEMF, PHOTON indicators will light up
on the screen.
HEAT + PEMF (1 - 30 Hz)
CONTROLLER
INSTRUCTION MANUAL