Healthy Climate Solutions HEPA-20 Homeowners Manual & Dealer Installation Instructions Download Page 1

AIR CLEANERS/

FILTERS

HEALTHY CLIMATE®

HEPA BYPASS AIR FILTRATION SYSTEM

504,887M

04/2010

HOMEOWNERS MANUAL & DEALER INSTALLATION INSTRUCTIONS 

FOR HEALTHY CLIMATE® MODELS HEPA-20, HEPA-40, HEPA-60

 Rules for Safe Installation and Operation

 Shipping and Packing List

Risk of property damage, injury or death.

Installation, adjustments, alterations, service and 

maintenance must be performed by a Healthy 

Climate® dealer.

!

WARNING

Risk of Carbon Monoxide Poisoning.

Can cause injury or death.
Do not operate equipment without access panel in 

place. Operation of this equipment without all access 

panels in place may cause gas fumes from the heat-

ing system to be drawn into occupied spaces.

!

WARNING

READ AND SAVE 

THESE INSTRUCTIONS!

Please read instructions before installing and using the 

HEPA Bypass Air Filtration System (HEPA system).  

This will help you obtain the full benefit of the HEPA 

system you have selected. It will also help you to 

avoid needless service costs.

1.

  Read this manual carefully.  Failure to follow these 

rules and instructions could cause a malfunction of 

air filter or unsatisfactory service and could void 

your warranty.

2.

  Follow a regular service and maintenance schedule 

to ensure efficient operation.

3.

  For safety and optimized performance of your 

HEPA system, all installation and maintenance 

must be performed by a Healthy Climate® dealer. 

The  installer should be made aware of your 

indoor air quality situation and be familiar with your 

heating, ventilation and air conditioning equipment.

4.

 Remove HEPA cartridge packing materials before 

initial start-up of this product.

Remove safety screws from HEPA filter access 

panel.

Unlatch the four retaining clips and lift off HEPA 

filter access panel.

Remove and discard the cardboard packing 

material between the HEPA cartridge and the filter 

access panel.

Ensure HEPA cartridge is installed and locked into 

place (brace the unit, press HEPA cartridge down 

and turn it clockwise to lock it into place.)

Replace the HEPA filter access panel and latch it 

with the four retaining clips.

Re-install safety screws into HEPA filter access 

panel.

5.

  High particulate distribution may occur during initial  

start-up of this product after installation or after 

scheduled filter changes.  Individuals who are  

highly sensitive to airborne particulates should not  

be in the building and allow 24 hours of operation  

for removal of particulates from occupied spaces  

before re-entry.

a.

b.

c.

d.

e.

f.

Package 1 of 1 contains:

1 - HEPA System 

1 - Complete Filter Set (Packed inside Unit) 

1 - Warranty Certificate 

1 - Installation Instructions (this manual)

 HEPA System Models

HEPA-20 (X4912)  is designed to filter air up to a 

rate of 180 cfm
HEPA-40 (X4913)  is designed to filter air up to a 

rate of 320 cfm
HEPA-60 (X4914)  is designed to filter air up to a 

rate of 500 cfm

Electrical Shock Hazard.

Can cause injury or death.
Disconnect all electrical power supplies 

before servicing.
Do not operate equipment without 

access panels in place

!

WARNING

Summary of Contents for HEPA-20

Page 1: ...aware of your indoor air quality situation and be familiar with your heating ventilation and air conditioning equipment 4 Remove HEPA cartridge packing materials before initial start up of this produc...

Page 2: ...ay shorten the life of the carbon canister Under normal conditions the carbon canister will last up to 6 months Initially the HEPA filter s particulate removal efficiency improves with use However the...

Page 3: ...and odors from the air OPTIONAL UPGRADE The stage 3 Inner Carbon Filter may be replaced by an optional heavy duty granulated coconut shell carbon canister The VOC Canister offers increased capacity r...

Page 4: ...abinet Filter Section Optional Coconut Shell Carbon Canister HEPA Cartridge Parts figure 1 figure 3 figure 4 figure 2 Motor Impeller Filter Adapter threaded O Ring Specifications HEPA 20 HEPA 40 HEPA...

Page 5: ...1 75 410 718 254 203 44 HEPA 60 16 13 28 25 10 0 8 0 1 75 410 718 254 203 44 F G H I J HEPA 20 2 0 1 0 9 0 15 25 1 4 51 25 229 387 36 HEPA 40 6 5 1 0 11 0 17 875 1 875 165 25 279 454 48 HEPA 60 6 5 1...

Page 6: ...s of dust humidity or chemicals found in your ambient air Additionally people who are more sensitive to these air borne contaminates may desire more fre quent filter changes Filter Changing Guidelines...

Page 7: ...other end of the clip once the carbon pre filter is stretched tight to lock the clip into place as shown in figure 15 Release clip it should hold tight on both ends of the carbon pre filter keeping it...

Page 8: ...an cause injury or death Disconnect all electrical power supplies before servicing Do no operate equipment without access panels in place Do not use this fan with any solid state speed control device...

Page 9: ...irectly into the return air elbow of the main return To reduce static pressure install outlet with a 45 degree takeoff directly up line from the return air elbow If the unit is being installed indepen...

Page 10: ...s should be as straight as possible if the duct runs are too long reduced CFM may result If duct is exposed to unconditioned air externally insulated flex duct is highly recommended Externally insulat...

Page 11: ...ers are recommended to help distribute airflow evenly in the occupied space Ducting If HEPA system is installed where inlet and outlet collars face down metal elbows must be connected to both inlet an...

Page 12: ...8 15 for optimal VOC Aldehyde removal Other Recommeded HEALTHY CLIMATE Products Ventilation Control System LVCS X4141 Humiditrol Whole Home Dehumidification Systems EDA 024B 94M41 EDA 036C 94M42 EDA 0...

Reviews: