CONNECT DRAIN LINE HERE

YELLOW

24 V

SOLENOID

VALVE

WIRES

WATER SUPPLY

SHUT-OFF

(SADDLE VALVE)

NOTE

VERIFY THAT MODE SWITCH
IS IN THE “BYPASS” POSITION.

NOTE

DO NOT WIRE TRANSFORMER
USING FURNACE BLOWER CIRCUIT.

AUTOMATIC
HUMIDIFIER

CONTROL

LO

HI

C

24V

ODT

H

C

R

P

O

W

E

R

B

Y

P

A

S

S

24 VAC FURNACE ACCESSORY TERMINALS

(10 VA MINIMUM) OR 24 VAC TRANSFORMER

(10 VA MINIMUM)

CURRENT

SENSING

RELAY

(IF REQUIRED)

FURNACE

BLOWER MOTOR

COMMON

MOTOR

LEAD

NOTE

CURRENT SENSING RELAY
REQUIRED IF TRANFORMER
IS CONSTANTLY POWERED.

FURNACE

BLOWER MOTOR

WATER SUPPLY

HI

C

LO

CONNECT DRAIN LINE HERE

CURRENT SENSING RELAY

(IF REQUIRED)

SHUT-OFF

(SADDLE VALVE)

YELLOW 24 V

SOLENOID

VALVE WIRES

24 VAC FURNACE

ACCESSORY TERMINALS

OR TRANSFORMER
(10 VA MINUMUM)

COMMON LEAD

MANUAL

HUMIDIFIER CONTROL

IMPORTANT

USE 120 VAC POWER SOURCE OTHER THAN FURNACE MOTOR
CIRCUIT. HOWEVER, THE TRANSFORMER CAN BE POWERED OFF
THE HOT 120 VAC LINE BEFORE IT ENTERS THE FURNACE.

• DO NOT WIRE TRANSFORMER INTO FURNACE BLOWER CIRCUIT.

IMPORTANT

WHEN CURRENT SENSING RELAY IS USED:

• WIRE CURRENT SENSING RELAY INTO 24 VAC HUMIDIFIER

CONTROL CIRCUIT ONLY!

DO NOT INSTALL IN TRANSFORMER

PRIMARY CIRCUIT.

The humidifier can be installed on either the

supply or return plenum of a forced air

handling system and is easily reversible for

installation with right hand or left hand

bypass duct connections. The humidifier

dimensions and serviceability must be

considered when selecting the best location

for the humidifier. Here are 2 examples of

many types of installations.

Horizontal

Upflow

90-1452

INSTALLATION OPTIONS

TEMPLATE MUST BE LEVEL

WARNING

SPECIFICATIONS

HUMIDIFIER DIMENSIONS

Width

(including solenoid valve):

15

3

8

Height

(including drain spud):

15

3

4

Depth

:

10

1

4

BYPASS DUCT OPENING

6” diameter

PLENUM OPENING

10”W x 12

3

4

”H

WATER FEED RATE

3 gph

ELECTRICAL DATA

24 VAC-60 Hz, 0.5 AMP

CAUTION

1. Water heating system can be damaged if water

supply remains off.

2. After humidifier installation is completed, turn hot

water supply back on.

3. Water heating system must be de-energized if the

main water supply remains shut off.

4. Do not set humidity level above recommended or to

recommended level if condensation exists on inside
windows of any unheated space, as condensation
damage may result. Excess humidity can cause
moisture accumulation which can allow the
possibility for mold growth in your home.

5. Do not install humidifier in location where freezing

temperatures may occur. The water line could freeze
and crack causing water damage to the home.

6. Do not install humidifier or bypass connection

on furnace cabinet.

7. Do not install humidifier or bypass connection

on blanked off end of cooling coil where
airflow will be restricted.

8. Do not connect the transformer to blower

motor wiring. Premature component failure
may result.

9. Do not install humidifier where water

pressures exceed 125 psi, since humidifier
damage may result. Follow codes in effect
concerning pressure reduction.

10. Do not install humidifier on systems with

greater than 0.4 in. wg pressure differential
between supply and return plenums.

RISK OF PROPERTY AND EQUIPMENT DAMAGE.

INSTALLATION INSTRUCTIONS AND TEMPLATE FOR HEALTHY CLIMATE LARGE BYPASS

HUMIDIFIER MODELS HCWB3-17, HCWB3-17K, HCWB3-17A & HCWB3-17AK

HUMIDIFIER

HEALTHY CLIMATE

®

HUMIDIFIERS

506366-01
4/2011

(Supersedes 7/2009)

1.

ELECTRICAL SHOCK HAZARD.

Can cause injury or death.
Disconnect all electrical power
supplies before servicing.

2.

RISK OF PROPERTY DAMAGE, INJURY OR
DEATH.

Installation, adjustments, alterations,

service and maintenance must be performed
by your Lennox dealer.

3.

RISK OF SCALDING.

Water temperature over

125°F can cause severe burns and scalding
instantly. Shut off the hot water supply before
disconnecting or tapping into any hot water
supply line.

4.

RISK OF SHARP EDGES HAZARD.

Equipment

sharp edges can cause injuries. Avoid grasping
equipment edges without protective gloves.

READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING

This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.

This product must be installed in compliance with all local, state and federal codes.

ATTENTION INSTALLER:

90-1433

90-1478

RETURN

AIR

SUPPLY

AIR

COOLING

COIL

FLUE

RETURN

AIR

SUPPLY

AIR

COOLING
COIL

RECOMMENDED WIRING DIAGRAMS

Model HCWB3-17 & HCWB3-17K

MANUAL CONTROL

For detailed Manual Humidifier Control installation
and wiring instructions, see Publication No. 506407−01
included with Control.

Models HCWB3-17A
& HCWB3-17AK

AUTOMATIC HUMIDIFIER CONTROL

For detailed Automatic
Humidifier Control installation
and wiring instructions, see
Publication No. 504,879M
included with Control.

TRACE ALONG OUTER EDGE

WARNING

Cover on humidifier must be securely in
place when blower is operating. Gas fumes,
which could contain carbon monoxide, can
be drawn into living space resulting in
personal injury or death.