![HBM WTX120 Operating Manual Download Page 80](http://html1.mh-extra.com/html/hbm/wtx120/wtx120_operating-manual_2111754080.webp)
Application
78
A4500-1.1
HBM: public
WTX120
8.2.4
Mode: Inside band
Weight
Time
Out
Lower band
Band span
Low lim / Band height
In Inside band mode, Low lim and Band height define a band. Within that band,
the relevant limit status is set. The limit is then likewise set on a preconfigured
digital output (e.g.
output 3 GW1
).
As soon as the level is outside the band again, the limit status is reset.