Electrical connection
T40B
A03452_15_X00_00
HBM: public
39
pin 2 (
) of plugs 1 or 3. We recommend that you use HBM cable KAB
8/00-2/2/2 and the appropriate sockets (see Accessories). The cable can be up
to 50 m long for voltages
≥
24 V, otherwise it can be up to 20 m long.
If the permissible cable length is exceeded, you can feed the supply voltage in
parallel over two connection cables (plugs 1 and 3). This enables you to double
the permissible length. Alternatively, install an on‐site power supply.
Important
The instant you switch on, a current of up to 4 A may flow and this may switch
off power supplies with electronic current limiters.