HBM SomatXR CX23-R User Manual Download Page 1

CX23-R and EX23-R

SomatXR Ultra-Rugged DAQ

User Manual

English

Summary of Contents for SomatXR CX23-R

Page 1: ...CX23 R and EX23 R SomatXR Ultra Rugged DAQ User Manual English...

Page 2: ...info hbm com www hbm com HBM Inc 19 Bartlett Street Marlborough MA 01752 USA Tel 1 800 578 4260 info usa hbm com Mat DVS a4275 8 0 en HBM public 03 2018 HBM Inc Subject to modifications All product d...

Page 3: ...om a vehicle 29 3 Configuring the system 33 3 1 Configuring network settings 33 3 2 Managing users and privileges 34 3 3 Configuring MX modules for use with the CX23 R 35 3 4 Updating main processor f...

Page 4: ...4 4 14 Smoothing filter 60 4 4 15 State mapper 61 4 4 16 Statistics 62 4 4 17 Time base shifter 63 4 4 18 Time channel 63 4 4 19 Timed trigger 63 4 4 20 Track 64 4 4 21 Triggered latch 64 4 4 22 Trig...

Page 5: ...lifier 87 5 3 3 MX1601B R Standard Module Universal Amplifier 89 5 3 4 MX1609KB R Thermocouple Amplifier 91 5 3 5 MX411B R Highly Dynamic Universal Module 92 5 3 6 MX460B R Frequency Counter Module 95...

Page 6: ...ications 150 6 7 6 FTP Servers 152 6 7 7 Date and time 153 6 7 8 Firmware 153 6 7 9 System preferences 154 6 7 10 Customer support 157 6 8 Test configuration 158 6 8 1 Test setup 158 6 8 2 Hardware 16...

Page 7: ...CX23 R and EX23 R a4275 8 0 en HBM public 7 7 7 Shunt scaling based on a known shunt scaling 192 7 8 SIE file metadata 192 7 9 SIE file size issues 197...

Page 8: ...ng error signaling limit value switches and such Safety rules A module must not be connected directly to a power supply network The maximum permissible supply voltage is CX23 R modules 10 VDC 30 VDC E...

Page 9: ...ule must have read and understood the User Manuals and in particular the technical safety instructions Remaining dangers The scope of supply and performance of the module covers only a small area of m...

Page 10: ...ts may be required to limit electromagnetic emissions Conversions and modifications The module must not be modified from the design or safety engineering point of view except with our expressed agreem...

Page 11: ...e Meaning Electric shock hazard Devices marked with this symbol may allow improper use to result in an electric shock Please observe handling instructions for components capable of delivering an elect...

Page 12: ...Safety instructions 12 a4275 8 0 en HBM public CX23 R and EX23 R NOTE Meaning Important information Points out important information about the product or its handling...

Page 13: ...terfaces including digital inputs and outputs three CAN ports one GPS and one auxiliary port AUX EX23 R Ethernet switch The EX23 R is a ruggedized 10 port Gigabit switch that supports IEEE1588 PTPv2 t...

Page 14: ...ublic CX23 R and EX23 R functions are not supported Interactive zeroing of the crank shaft sensors is not supported MX471B R CAN Module Up to four 4 independent CAN bus nodes electrically isolated fro...

Page 15: ...alf bridge five wire configuration 99 Strain gage quarter bridge three or four wire configuration 3 wire only 3 wire only 99 Inductive full bridge 102 Inductive half bridge 102 LVDT linear variable di...

Page 16: ...nectors 5 8 117 Torque speed connectors 5 8 117 Passive inductive encoder 123 PWM Pulse width pulse duration period duration 123 Crank wheel sensors 131 SSI protocol connectors 5 8 117 CAN bus databas...

Page 17: ...s direct data sourcing for six interfaces including one DIO three CAN one GPS and one AUX The CX23 R back panel includes the input power and AUX power ports power switch status LEDs and Ethernet commu...

Page 18: ...be compatible with the system default IP address 192 168 100 101 3 Connect desired transducers to DIO GPS AUX and CAN ports using the appropriate sensor cables Refer to the SomatXR Accessories Data Sh...

Page 19: ...o save changes 5 In the header click the Control button to navigate to the Test and data control section In the Task pane Test control shows 6 To view real time data select a check box by a name in th...

Page 20: ...NOTE Connect only the red and black wires of the 1 KAB2115 cable Do NOT use a 1 KAB2110 cable to power the EX23 R from the CX23 R 2 Connect the desired devices to the Ethernet ports using 1 KAB2100 1...

Page 21: ...When using FireWire to power MX modules make sure that all modules have an Ethernet connection to the CX23 R unit or EX23 R switch Failure to do so may cause undetected synchronization errors in all...

Page 22: ...s may also be powered in serial using FireWire connections Refer to the MX Modules User Manual for details 2 Use a 1 KAB2107 cable to connect the CX23 R ETHERNET1 connector to the EX23 R switch NOTE F...

Page 23: ...ware 1 Connect an antenna to the Sierra Wireless gateway 2 Refer to Sierra Wireless documentation for connecting the gateway to a power source 3 Connect the CX23 R to a 10 30VDC power supply 4 Connect...

Page 24: ...dress is 192 168 100 101 Configuring an EX23 R Switch for connecting the access point To effectively use Power over Ethernet bandwidth and security to avoid broadcasting packets to other ports set up...

Page 25: ...1 port 5 Use a 1 KAB2107 X cable to connect the CX23 R ETHERNET 1 port to EX23 R 2 port ACKSYS WLg xROAD N or WLg xROAD NP access point The ACKSYS WLg xROAD access point is an industrial 802 11 a b g...

Page 26: ...R default IP address is 192 168 100 101 Configuring an EX23 R Switch for connecting the access point To effectively use Power over Ethernet bandwidth and security to avoid broadcasting packets to othe...

Page 27: ...d separately appropriately sealed for your application 2 Use a 1 KAB2106 X cable to connect the adapter to EX23 R 10PoE port 3 Install caps on the WLg xROAD power wires 4 Connect the EX23 R and CX23 R...

Page 28: ...efer to video device manufacturer s documentation for video image rotation which may be limited to 180 or 90 degree increments Compatible camera devices The SomatXR eDAQXR system is compatible with th...

Page 29: ...tor The remote power switch acts as a three way household switch in conjunction with the CX23 R power push button Connect the 1 KAB2115 2 green and black wires to two contacts of a single pole single...

Page 30: ...with a direct connection to a vehicle battery that has a permanent ground connection to the vehicle chassis Vehicle electrical system or harness An alternate method shown below uses a vehicle electri...

Page 31: ...ves the negative battery terminal from the equipment chassis ground carefully follow the illustrated recommendation below CAUTION Failure to follow these suggestions may result in blown fuses and or p...

Page 32: ...2 Setting up the hardware 32 a4275 8 0 en HBM public CX23 R and EX23 R...

Page 33: ...may be edited as necessary DNS server assignment For static IP assignment manually format the Preferred and Secondary DNS servers Select Dynamic Obtain IP address configurations automatically DHCP Dyn...

Page 34: ...ing a new profile Navigate to the Profiles page under System Configuration To create a profile click New Enter the profile name select the desired privileges and click Save Creating a user and assigni...

Page 35: ...urement capabilities using 24 bit ADCs TEDS sensor support and multiple digital filtering options All MXB modules have a similar back panel with a power connector two FireWire connectors and one Ether...

Page 36: ...rate multiply the nominal sample rate by 8388608 8386425 3 4 Updating main processor firmware HBM regularly releases new firmware introducing new features and providing device improvements CAUTION Al...

Page 37: ...e data from transducer channels or other computed channels 4 Create DataModes to store channel and computed channel data 4 2 Configuring input channels 4 2 1 Configuring TEDS sensors To simplify input...

Page 38: ...hannels and click OK 4 2 3 eDAQ CAN databases To simplify CAN channel configuration the CX23 R EXRCPU supports eDAQ CAN databases in a txt format See Databases Page 147 for importing instructions Addi...

Page 39: ...e Configuring TEDS sensors for more information SDB For MX module channels with HBM sensor databases applied an icon is displayed with the SDB status Not in edit dialog Reading Current value of the ch...

Page 40: ...Range min max value Chart type Set the default chart type for the channel Not in edit dialog Decimals Select the default decimal places for channel displays Use the Auto option to apply the settings d...

Page 41: ...ctrical units of channel input This is fixed by the system and cannot be changed The defined sensor scaling is used to convert data from Electrical units to Physical units Units Physical units of meas...

Page 42: ...modified before or after the Electrical 1 and Electrical 2 values are measured Click MEASURE 1 to take the first reading electrical 1 Then click MEASURE 2 to take the second reading electrical 2 Both...

Page 43: ...and range revert to the user defined values after shunt scaling is completed or canceled In this situation the channel requires zeroing and the GUI prompts the user to do this Perform shunt scaling i...

Page 44: ...nominal gage resistance Rsk known shunt resistance Rse equivalent shunt resistance Equivalent strain calculator This shunt tool is only applicable when the shunt scaling mode is selected Calculation...

Page 45: ...le channels If the type is Full or Half bridge the value must be 90 5000 If the type is Quarter bridge the value must be 120 or 350 user selectable Leadwire Ohms For applicable strain gage bridge sens...

Page 46: ...mental encoders The following three configuration parameters are applicable Quadrature For Digital timer inputs Incremental encoder inputs set to True to count in quadrature Encoder index reset For en...

Page 47: ...itted during a test run Technical Note CAN Message ID Masking For each signal a CAN database file specifies which CAN message ID or IDs carry the signal the bit position and length of the signal withi...

Page 48: ...ower option selected As such always power off the SomatXR eDAQXR system before connecting a Garmin GPS if an EGPS 200 or EGPS 200 Plus module was previously connected All GPS modules source standard N...

Page 49: ...e any real number greater than zero Invalid value Specify the value to be set when the expiration time has elapsed without any data The value may be any real number 4 3 6 System channels System channe...

Page 50: ...a or video hardware connected through an EX23 R PoE Switch See Setting up an Axis network camera for more information Network node Select the network node that will process the video data stream Since...

Page 51: ...x value on the multiplot The timestamp is test run time To calculate the real time view the test start time in the metadata viewer and add the x value in seconds It is possible for the test not to re...

Page 52: ...s the selected parameters and outputs a status for each specified window Use with a Bitmap trigger computed channel to generate triggers based on the anomaly detection NOTE The Description is initiali...

Page 53: ...defined anomaly is detected Bitmap check mode Set the trigger mode for the computed channel o Any bit in mask set If any bit in the specified bit mask is set the output value is TRUE otherwise it is...

Page 54: ...ate a signed angular velocity output channel for a rotary encoder In this example the velocity channel is typically the A or B signal lines from a DIO frequency channel The direction channel is typica...

Page 55: ...Integrator computed channel generates an output that is the integral of the input channel As long as the integrator is not reset or suppressed each output sample is the cumulative sum of the current a...

Page 56: ...Boolean true i e 1 when any input channel data sample exceeds a defined Alarm max or Alarm min value in the test engine frame period otherwise the output is set to Boolean false i e 0 The output can...

Page 57: ...ncy is detected or until 10 seconds 1 f have elapsed at that point the output value is set to 0 1 Hz This minimum output frequency is also the initial output value until the first pulse is detected NO...

Page 58: ...Expression Double click or drag and drop a channel or operator to add it to the Expression panel Alternatively build the expression using keyboard entry All operators and referenced input channels are...

Page 59: ...tion of a sgn sgn a 1 for a 0 1 for a 0 0 for a 0 float float a Logical channel a converted to floating point floor floor a The largest integer less than or equal to a ceil ceil a The smallest integer...

Page 60: ...e in the set of computed channels However intermediate variables have been used above to clarify the general approach 4 4 14 Smoothing filter The Smoothing filter computed channel generates an output...

Page 61: ...e from switching for at least this period of time This feature can eliminate state switching transients in the output channel data stream If the latch period is zero the output state switches on each...

Page 62: ...ode specify the X value as an integer between 0 and 100 The output is the value at the Xth percentile of the sample window If necessary an output value is interpolated between the input values that bo...

Page 63: ...he first n 1 output samples with the initial value of the input channel 4 4 18 Time channel The Time channel provides a time base channel for use with other computed channels or for storage in the Tim...

Page 64: ...el A logical trigger channel can be used to reset the tracker Mode Set the tracker mode to Min track Max track or Range track Trigger reset options Enable triggered reset If selected the tracker reset...

Page 65: ...Set the trigger channel used to suppress the input channel Mode Set the condition for suppressing the input channel o When true Suppress the input channel when the trigger channel is TRUE o On false...

Page 66: ...reams for each channel Signal 1 refers to the signal generated using the input channel parameterization Signal 2 uses the same parameterization with the following exceptions o The sample rate is set t...

Page 67: ...me Each DataMode must have a unique name and contain only valid characters invalid characters are single and double quotes and Invalid channel names are true and false case sensitive Description Optio...

Page 68: ...ode is used burst storage is terminated after the total burst data samples stored exceeds the size of the specified number of burst records times the Standard burst record size NOTE The total number o...

Page 69: ...values at the start of each test run Trigger mode Select one of four available triggering options Use triggering to eliminate undesired segments of the input data stream before it is processed by the...

Page 70: ...Select one of four available triggering options Use triggering to eliminate undesired segments of the input data stream before it is processed by the DataMode o Always on Do not use triggering Data s...

Page 71: ...e peak When the difference between the candidate values exceeds the hysteresis level the candidate valley value is stored The algorithm switches to Peak search 4 6 7 Peak valley matrix The Peak valley...

Page 72: ...of the three available modes o Range Mean Accumulate counts in bins with range and mean dimensions o Range only Accumulate counts in bins with only a range dimension o To From Accumulate counts in bi...

Page 73: ...t the logical input channel for triggering when using a trigger option other than Always on The trigger channel must have the same sample rate as the selected input channels DataModes options Hysteres...

Page 74: ...ut peak valley sequence assuming that the sequence repeats itself However to support proper rainflow histogram addition that is generating a composite rainflow histogram from multiple rainflow histogr...

Page 75: ...appropriate list 4 6 10 Time history The Time history Data Mode stores multiple channels of triggered or un triggered time history data streams in the output data file All channels must have the same...

Page 76: ...r executable exe file to the computer from the USB flash drive delivered with the main processor or from the www hbm com website 2 Double click the file icon to install XR Download Manager 3 Respond t...

Page 77: ...ions for three sensor input lines two current sinking output lines one power output line and individual shield ground connections for all five input and output lines Digital input channels have an inp...

Page 78: ...trol lines to communicate with the Somat EGPS 5HZ module The CX23 R processes standard NMEA formatted GPS messages to provide navigation and time channels at 5 Hz update rates See GPS channels Page 48...

Page 79: ...4 Hz 4 Hz Off Firmware update 1 Applying firmware update and rebooting Off 4 Hz Off P 2 Checking FPGA 4 Hz 4 Hz 4 Hz On Previous state or state dependent LED sequence for power button shut down Blue...

Page 80: ...re color 1 KAB2109 2 pin side of cable 1 CAN Ground Yellow 2 CAN Power 10 30 V Red 3 Ground Black 4 CAN_H White 5 CAN_L Blue 5 1 5 CX23 R DIO pin assignments Connector PIN Description Wire color 1 KAB...

Page 81: ...7 5 GPS PPS Gray 6 Input control Pink 7 Ground Black 8 Power Red 5 2 EX23 R PoE Switch 5 2 1 EX23 R status LEDs Power LED Description Off Power input not in range On Unit is powered Flashing 2 Hz Powe...

Page 82: ...net connector MXB modules can be connected to a CX23 R module directly or through one or more EX23 R Ethernet switches For more information on setting up a system with MXB modules see Connecting MX mo...

Page 83: ...ncluding strain gage based transducers standardized voltage and resistance or resistance based measurements MX840B R Universal Module Up to eight 8 universal inputs for connecting more than 16 transdu...

Page 84: ...inal data skew between the analog output and the source input to the associated MX module channel is nominally 3 milliseconds when no digital filters are used MX840B Universal Module Up to eight 8 uni...

Page 85: ...istance thermometer RTD PT100 or PT1000 112 Thermocouple 113 Frequency pulse counter timer TTL connectors 5 8 117 Torque speed connectors 5 8 117 SSI protocol connectors 5 8 117 CAN bus database or ra...

Page 86: ...s running All orange flashing Download is active Orange Connection is newly assigned transducer identification is running CAN data received but bus is occasionally disturbed buffer overflow individual...

Page 87: ...nsor supply 5 24 V Yellow 11 Sense f2 Grey 12 Sense f2 Green 13 TEDS Ground frequency measurement Grey Black 14 TEDS Green Black Shield Shield NOTE Connection between pins 4 and 5 is necessary for all...

Page 88: ...voltage or 1200 Hz AC square wave carrier frequency with an amplitude of 0 5 1 2 5 or 5 volts The measurement channels are electrically isolated from the power supply and the interfaces When TEDS or T...

Page 89: ...in gage transducers Resistance based measurements and Resistance based measurements inputs For more information refer to the wiring diagrams NOTE Connection between pins 1 and 11 is necessary for all...

Page 90: ...wer When using transducer excitation electrical isolation from the supply voltage of the amplifier is rescinded Status LED The following table gives the descriptions for all LED states System LED Desc...

Page 91: ...or connector must have a connection between pins 1 and 11 for compatibility with the MX1615B R module The adjustable transducer excitation between 5 and 24 volts is only available on channels 1 throug...

Page 92: ...sensor scaling is running Red No sensor connected Channel error incorrectly parametrized connection error invalid TEDS data Overload of sensor supply 5 3 5 MX411B R Highly Dynamic Universal Module Up...

Page 93: ...G120 2 or 1 SCM R SG350 2 Use ODU 14 pin to BNC adapter 1 KAB430 0 3 The measurement channels are electrically isolated from each other and from the power supply When using the adjustable transducer e...

Page 94: ...zation connection error invalid TEDS data overloaded sensor supply MX411B R pin assignments Connect sensors via the 14 pin ODU MINI SNAP connectors Connector Pin Connection Wire color 1 KAB183 or 1 KA...

Page 95: ...connected via a 14 pin ODU device socket All measuring channels are electrically isolated from one another and from the mains When using the adjustable transducer excitation electrical isolation from...

Page 96: ...stem is not ready download is active Orange Connection newly assigned transducer identification running calibration Flashing green 5s then green TEDS data being read in Flashing orange 5s then green M...

Page 97: ...rown 10 Active sensor supply 5 24 V Yellow 11 Frequency input f2 Grey 12 Frequency input f2 Green 13 TEDS Signal ground Grey Black 14 TEDS Green Black Shield Shield NOTE Connection between pins 4 and...

Page 98: ...w System is not ready boot procedure is running Yellow flashing System is not ready download is active Red System error faulty synchronization CAN LEDs BUS Description Green flickering Bus is error fr...

Page 99: ...N L Blue 5 4 Inputs and wiring diagrams 5 4 1 Strain gage transducers Transducer MX840B R MX1615B R MX411B R Strain gage full bridge six wire configuration Strain gage half bridge five wire configurat...

Page 100: ...dge configurations a connection between the sense lead and excitation lines must be made in the connector Half bridge strain gage NOTE For half three wire bridge configurations a connection between th...

Page 101: ...R hardware CX23 R and EX23 R a4275 8 0 en HBM public 101 NOTE The quarter bridge three wire configuration with sense line can be used with the CX23 R catman AP or MX Assistant which support up scale s...

Page 102: ...configuration without sense lines can be used only with the CX23 R which supports down scale shunting It is not supported by catman AP or MX Assistant 5 4 2 Inductive transducers Transducer MX840B R...

Page 103: ...5 SomatXR hardware CX23 R and EX23 R a4275 8 0 en HBM public 103 Inductive full bridge...

Page 104: ...5 SomatXR hardware 104 a4275 8 0 en HBM public CX23 R and EX23 R Inductive half bridge...

Page 105: ...5 SomatXR hardware CX23 R and EX23 R a4275 8 0 en HBM public 105 Linear variable differential transformer LVDT 5 4 3 Piezoresistive transducers Transducer MX840B R MX411B R Piezoresistive transducer...

Page 106: ...5 SomatXR hardware 106 a4275 8 0 en HBM public CX23 R and EX23 R 5 4 4 Potentiometric transducers Transducer MX840B R MX1615B R Potentiometric transducer...

Page 107: ...5 SomatXR hardware CX23 R and EX23 R a4275 8 0 en HBM public 107...

Page 108: ...23 R and EX23 R 5 4 5 Voltage sources Transducer MX840B R MX1615B R MX1601B R MX411B R Voltage 60 V 10 V 100 mV 60 V only 10 V only 100 mV DC Voltage Source 10 or 60 V DC Voltage Source NOTE Maximum i...

Page 109: ...table sensor supply 5 4 6 Current fed piezoelectric transducers IEPE ICP Current fed piezoelectric transducers are supplied with a constant current and output a voltage signal to the amplifier This ty...

Page 110: ...ardware 110 a4275 8 0 en HBM public CX23 R and EX23 R NOTE IEPE transducers with TEDS version 1 0 are supported 5 4 7 Current sources Transducer MX840B R MX1601B R MX411B R Current 20 mA 20 mA DC Curr...

Page 111: ...5 SomatXR hardware CX23 R and EX23 R a4275 8 0 en HBM public 111 NOTE Maximum current is 30 mA 20 mA Current fed DC Current Source NOTE Maximum current is 30 mA...

Page 112: ...supply must be connected in series This however terminates the electrical isolation to the module supply 5 4 8 Resistance based measurements Transducer MX840B R MX1615B R Resistance or resistance bas...

Page 113: ...nd EX23 R a4275 8 0 en HBM public 113 Resistance Thermometer RTD 5 4 9 Thermocouples Transducer MX840B R MX1609KB R Thermocouple K type only Use thermocouple adapter 1 SCM R TCK 2 for K type other typ...

Page 114: ...5 SomatXR hardware 114 a4275 8 0 en HBM public CX23 R and EX23 R 5 4 10 Digital inputs Transducer CX23 R Digital input Frequency Pulse counter Duty cycle Single pole double throw switch...

Page 115: ...5 SomatXR hardware CX23 R and EX23 R a4275 8 0 en HBM public 115 Single pole single throw switch Driven signal 5 4 11 Digital outputs Transducer CX23 R Digital output...

Page 116: ...5 SomatXR hardware 116 a4275 8 0 en HBM public CX23 R and EX23 R Sensing circuit Load with external power source Load powered by CX23 R...

Page 117: ...n HBM public 117 5 4 12 Digital timer inputs Transducer MX840B R MX460B R Frequency pulse counter timer TTL connectors 5 8 Incremental encoder timer TTL connectors 5 8 Torque speed connectors 5 8 SSI...

Page 118: ...5 SomatXR hardware 118 a4275 8 0 en HBM public CX23 R and EX23 R...

Page 119: ...5 SomatXR hardware CX23 R and EX23 R a4275 8 0 en HBM public 119 Incremental encoder...

Page 120: ...5 SomatXR hardware 120 a4275 8 0 en HBM public CX23 R and EX23 R Torque Speed HBM torque transducers...

Page 121: ...5 SomatXR hardware CX23 R and EX23 R a4275 8 0 en HBM public 121...

Page 122: ...5 SomatXR hardware 122 a4275 8 0 en HBM public CX23 R and EX23 R Absolute value encoder SSI protocol...

Page 123: ...23 R a4275 8 0 en HBM public 123 5 4 13 Passive inductive encoder Transducer MX460B R Passive inductive encoder 5 4 14 Pulse width pulse duration period duration PWM Transducer MX460B R PWM Pulse widt...

Page 124: ...5 SomatXR hardware 124 a4275 8 0 en HBM public CX23 R and EX23 R...

Page 125: ...1 SCM R SG120 2 or 1 SCM R SG350 2 NOTE To ensure normal operation the CAN bus needs to be terminated at both ends using appropriate termination resistors The CX23 R MX471B R and MX840B R provide inte...

Page 126: ...ing 12 volt transducer power to a 5 volt encoder may damage it Transducer power is limited to 3 W Check encoder data sheet to ensure the encoder and any necessary pull up resistors use less than 3 W t...

Page 127: ...a4275 8 0 en HBM public 127 For applications requiring long cable runs or more than 200K pulses per second use the differential wiring diagram below Place the 120 Ohm termination as close to the inpu...

Page 128: ...5 SomatXR hardware 128 a4275 8 0 en HBM public CX23 R and EX23 R...

Page 129: ...and any necessary pull up resistors use less than 3 W total The inputs are ground referenced not differential If using a differential output encoder like RS422 only connect the positive A B and Z outp...

Page 130: ...HBM public CX23 R and EX23 R For applications requiring long cable runs or more than 200K pulses per second use the differential wiring diagram below Place the 120 Ohm termination as close to the inpu...

Page 131: ...5 SomatXR hardware CX23 R and EX23 R a4275 8 0 en HBM public 131 5 4 17 Crank wheel sensors Transducer MX460B R Crank wheel sensors...

Page 132: ...5 SomatXR hardware 132 a4275 8 0 en HBM public CX23 R and EX23 R...

Page 133: ...CX23 R and EX23 R a4275 8 0 en HBM public 133...

Page 134: ...s recommended instead to use a secure HTTPS connection port 443 See Live data displays NOTE for information about using HTTPS and possible effects of antivirus software 6 2 Interface tour Navigate in...

Page 135: ...c 135 Header The Header contains the View buttons Test Setup titlebar and Quick Link buttons Click View buttons to show Task pane menu and action panels and associated workspaces More View button info...

Page 136: ...are Create and edit input channels computed channels output channels and DataModes Manage live update options Configure normal cyclic or remote control of test runs Manage test stop options Manage cha...

Page 137: ...ave User preferences Language Search filter of Workspace grid content and Help More Quick Link button information Save all Save all pending changes When changes are pending the icon is orange In Test...

Page 138: ...y work area and shows dialogs according to the Menu item selection The Workspace may contain a grid interface See Grid interface Page 139 for information about showing and hiding columns When a grid i...

Page 139: ...t until the user preferences are reset Sort and filter rows Grids can be sorted automatically by selecting Sort Ascending or Sort Descending from the drop down menu Rows are sorted according to the se...

Page 140: ...key moving up one cell the down arrow key moving down one cell and so on The Tab key will move the selection to the right and wrap around to the first cell once it reaches the end of the row The Enter...

Page 141: ...messages Filtering the system log Enter values in any or all of the From and To date and time fields Click Refresh to request the log entries in the selected range The specified range not only affects...

Page 142: ...dicator is hidden Select cell text on focus Select to automatically select all the text in an editable grid cell when it gains focus Use this setting to replace cell values instead of append text to e...

Page 143: ...a value of 200 pixels or more The default is 300 Chart type Select the type of chart that will be used most frequently The default is Strip chart This is used to set the SXR file chart type parameter...

Page 144: ...channels Select this option to show live updates for resampled channels such as CAN GPS and system channels Include computed channels Select this option to show live updates for computed channels Con...

Page 145: ...removing a profile assigned to a user affects new sessions only existing sessions are unaffected until the user logs out User privileges Hardware control Unselected View only access to Hardware Selec...

Page 146: ...s Changes apply to new sessions only existing sessions are unaffected until the user logs out Deleting a profile To delete a profile select the desired profile and click Delete A deleted profile is re...

Page 147: ...e Managing users and privileges Default user and restoring default credentials for more information 6 7 3 Databases The SomatXR eDAQXR system currently supports Vector CAN database files dbc eDAQ CAN...

Page 148: ...ses are currently supported only by the CX23 R eDAQXR CAN interface They are not currently supported by the MX471B R or MX840B R CAN interfaces HBM sensor database files sdbx Browse for and import the...

Page 149: ...For static assignment enter correctly formatted IPV4 address subnet mask default gateway and broadcast values Some fields are automatically populated based on the entered values but they may be edite...

Page 150: ...a common point of failure for properly configured server details which may still not work properly due to the SMTP server s configuration of requiring encryption Click a New Delete Save or Cancel but...

Page 151: ...e HBM Push app All messages are encrypted during transmission In the web interface click the New ID button and the Request Push ID dialog appears In the dialog enter a name appropriate for identifying...

Page 152: ...veral FTP server configurations can be defined but only the active configuration is used at test start time If no SIE files are to be transferred no FTP server configurations should be active See Cycl...

Page 153: ...ration from the FTP server list and click the Delete button The active FTP server configuration cannot be deleted Saving an FTP server configuration To save an FTP server configuration click the Save...

Page 154: ...l nominal sample rates include 4800 2400 1200 and 600 S s NOTE The nominal Classic domain sample rates are used for convenience The actual sample rates are approximately 260 ppm greater than the nomin...

Page 155: ...sibility of an infinite loop of error resets where the user does not have time to open the web browser interface and interactively stop the test The counter is set to the Max number of normal test res...

Page 156: ...y important unless the test is running at high CPU load i e 90 or higher SIE Filename pattern default Select between Numeric increment or Date and time suffix for automatic naming of SIE files For FTP...

Page 157: ...Delete databases This option deletes all internal databases within the unit Because of its destructive nature only those users with the highest security level are granted access to this area Only per...

Page 158: ...est selector in the header Test setup parameters Setup name The setup name must be unique and contain valid characters invalid characters are single and double quotes tab and Title Enter an optional t...

Page 159: ...ault Select between Numeric increment or Date and time suffix for automatic naming of SIE files For FTP uploads if the filename mode is Date and time suffix the extra timestamp normally put on the end...

Page 160: ...hannel is another option There are no restrictions on using multiple test stop options in the same test Stop on test duration Select the check box Set days 0 to 365 Set hours 0 to 23 Set minutes 0 to...

Page 161: ...d setup configuration Click Import See additional information in Importing or exporting a test setup below Deleting a test setup To permanently delete a setup from the device select the desired test s...

Page 162: ...ssign a new valid connector name to that channel 5 Exporting a channel defined via TEDS and or HBM SDB parameter assignment is supported however the traceability parameters are not currently included...

Page 163: ...nd FTP uploads if applicable However it is recommended that users periodically connect to the unit to verify that the connection is still available at a minimum Remote control run mode on the CX23 R T...

Page 164: ...or disconnected NOTE Connected EX23 R modules are not shown Devices such as cameras connected directly to an EX23 R appear under the CX23 R module Each module displays basic information including modu...

Page 165: ...he add icon For TEDS connected sensors the channel parameters are automatically defined For other channels use the presented dialog to set the channel parameters Applying sensor database parameters To...

Page 166: ...ct column in Test configuration However while sorting by the Collect column in the All input channels tab Computed channels will be sorted separately below other input channels The All channels view d...

Page 167: ...l parameters to TEDS sensor definition select the channel and click Sync TEDs Applying sensor database parameters To apply sensor configurations from imported HBM sensor databases first expand the Sen...

Page 168: ...target channel and click Paste to paste the copied parameters into the selected channel Only parameters that exist in the target channel are pasted For example DIO parameters cannot be pasted into an...

Page 169: ...ck ZERO to measure the current channel data value and adjust the cumulative zero offset which is stored in the Prerun zero offset channel parameter Click RESET to clear any previous zero offsets After...

Page 170: ...channels Anomaly detect Page 52 Bitmap trigger Page 53 Directional velocity Page 53 Down sampler Page 54 Function generator Page 54 Integrator Page 55 Interactive trigger Page 56 Over range detector P...

Page 171: ...The parameters depend on the selected channel type In addition parameters hidden in the grid view do not display in the copy dialog Click OK to copy the selected parameters Select the target channel a...

Page 172: ...py to only applicable channels are displayed To add a channel to the setup select the check box next to the channel or group of channels and click OK Editing an output channel Select the desired chann...

Page 173: ...e tabs only DataModes of that type are visible Tabs are automatically made visible when DataModes are created On a channels tab a number shows for total channels in the list To filter the channels lis...

Page 174: ...o edit the channel parameters using the DataMode dialog Alternately edit the DataMode parameters directly in the channel grid Select the All DataModes tab to edit common parameters and the DataMode ty...

Page 175: ...heck the box Enable Remote Control to initialize the remote control mode Typically the Suspend Remote Control box is not checked Click the OK button to close the dialog window The test run will start...

Page 176: ...r However for reasons beyond the scope of this help topic the web browser used can be a significant factor As of the present software version the user is strongly advised to use one of the recommended...

Page 177: ...al meter with alarms A Min Max chart is a digital display of minimum current and maximum data values for each channel Warning and alarm level exceedance indicators are provided on a per channel basis...

Page 178: ...aded or refreshed Controlling interactive triggers Interactive triggers provide a means to manually trigger computed channels and Data Modes during a test run Set up interactive triggers using one or...

Page 179: ...ton o Font Three font varieties are available Monospace takes less space sans serif improves legibility and serif is easiest to read Two additional formats are available bold and italic o Unit name pl...

Page 180: ...available from the menu Click the options menu button Freeze Select to pause the data display Deselect to resume live data Update rate Select the rate at which the display refreshes at 1 2 5 or 10 ti...

Page 181: ...a chart with multiple y axes select All Channels to use the same scaling mode for all channels otherwise select a specific channel to set the scaling mode for that channel only Scaling Select the Y ax...

Page 182: ...mes for the meter by specifying angular degree values that are cumulatively 360 degrees or less such as the defaults 135 and 135 o Min needle angle Specify the minimum angle for the extreme of needle...

Page 183: ...TE Change default chart options such as background color and grid display in User preferences After entering information in the Spectrum properties dialog click the OK button Output type Set the outpu...

Page 184: ...the vertical axis For Amplitude output types this value is in channel units For the Power output type this value is in decibels from peak and values are always negative or zero Min Max tracking of mu...

Page 185: ...In the Test configuration Hardware panel click the eye icon by the camera channel for video display In the Test control panel select the camera channel for video display in the Display Views panel Cha...

Page 186: ...the desired file and click Download Multiple SIE files can be downloaded by selecting multiple check boxes However only Chrome supports this well currently and that is subject to change See the topic...

Page 187: ...red extraction option Extract test configuration Enter the desired file name Click Export to save the file to the local machine Extract hardware information Enter the desired file name and click Expor...

Page 188: ...down list in the header A green bar to the right of a channel chart shows the view is selected Close a view by clicking the red X in the right hand corner of the channel chart View the value of a poin...

Page 189: ...GPS receiver as described above The current state of the oscillator regulation is displayed on the Setup Hardware page The unit will display Clock regulation GPS if a GPS signal is currently being us...

Page 190: ...once in QA testing Because on this the option to completely disable the front panel switch and also the remote power switch was added See Hardware Page 164 Controlling a module Reboot Flash LED Updat...

Page 191: ...s the MX module If this happens about 6 minutes of test data will be lost Summary All of the known issues with long term unattended testing have workarounds that will limit data losses to relatively s...

Page 192: ...the following formula Ve Vk Rg 2 Rsk Rg 2 Rse where Rg Bridge resistance Ohm Rsk Known shunt resistance Ohm Vk Known physical units value Rse Equivalent shunt resistance Ohm Ve Equivalent physical un...

Page 193: ...g MXB modules Axis cameras somat module_type EBRG Hardware module type marketing name somat network_node edaqxr 500016 User assigned Network node applicable for expansion modules only somat measurand...

Page 194: ...ined physical units range max somat digital_filter_type linear_phase_fir Digital filter type where applicable somat digital_filter_ attenuation_frequency 833 Digital filter attenuation frequency hbm_e...

Page 195: ...hannel data is flagged as stale or invalid somat can_bit_rate 1000000 CAN bit rate somat can_msg_id 0x000007B6 CAN message ID hex format somat can_bit_length 16 CAN signal number of bits somat can_bit...

Page 196: ...ry SSI encoding mode binary or gray somat ssi_clock 1000 SSI clock frequency kHz somat ssi_bits 22 SSI bits controls angular resolution somat sensor_id 430605296858 HBM SDB ID somat sensor_calibration...

Page 197: ...ll channels where any numerical processing is required The only exception to this are the MX channels that source data as 32 bit floats with no numerical processing required This includes the MX840 CA...

Page 198: ...e_rate 10 block_time 10 else if sample_rate 2 block_time 20 else if sample_rate 0 4 block_time 40 else block_time 80 bytes_per_block sample_rate block_time bytes_per_ sample if bytes_per_block 8000 by...

Page 199: ...he SIE file when the test is stopped SIE storage space is reserved for this to ensure they can be stored even if the SIE storage area is fully consumed during the test c When sequential DataModes such...

Page 200: ...a4275 8 0 en HBM public measure and predict with confidence HBM Inc Tel 1 800 578 4260 info usa hbm com www hbm com...

Reviews: