42
BPX001 Backplane
HBM
QuantumX
4.5.2
Wall mounting
A total of 10 boreholes are provided in the backplane for wall mounting (
∅
6.5 mm). We
recommend using the outer 4 boreholes for wall mounting.
NOTE
Only use countersunk head bolts for fastening, otherwise the modules cannot be
mounted correctly.
Fig. 4.18:
BPX001 drilling pattern and dimensions
Note the following information when installing one or more backplanes in a control cabinet:
•
When installing in a control cabinet, the temperature limits given in the technical data of
the backplanes must be complied with
•
Depending on the installation situation, sufficient ventilation (vertical air flow) or cooling
must be provided (the maximum total output on a backplane is approx. 150 Watt)
•
The ventilation slits of the modules must not be covered (e.g. by cable ducts)