QuantumX Data Recorder CX22‐W
18
A3169-1.0 en/de
HBM
QuantumX modules are connected to the CX22‐W Data Recorder via
FireWire in the same way as is the case with other QuantumX modules: e.g.
1‐KAB269‐x, connection X100 of the CX22‐W to X101 on the first module, this
module with connection X102 to X101 on the next module, etc. Alternatively,
you can also connect all QuantumX modules via Ethernet to the CX22‐W. If
you have more than one module, you will require an Ethernet Switch.
In the configuration shown below, the supply voltage of the modules is looped
through FireWire (maximum 1.5A via FireWire; power consumption for a
module or the CX22‐W, see the Technical Data Section in the data sheet).
You can connect up to 12 modules via FireWire to the CX22‐W Data
Recorder, supply feed required for every 4 modules. The QuantumX operating
manual contains more detailed data on this.
10V ... 30V
DC
FireWire connection
1‐Kab269‐x: Connection cable with various lengths (x m)
CX22(‐W)
Fig. 5.1:
Connecting QuantumX modules to the CX22‐W Data Recorder
5.4
Connecting other devices
Only QuantumX modules can currently be connected to the CX22‐W Data
Recorder. If you want to connect other devices, e.g. MGCplus, please contact