19
MP85A(DP) FASTpress, MP85A(DP)
−
S EASYswitch
A2073-5.0 en/de/fr
8
Displaying saved processes / Report printout
(
Data storage
window)
To ensure optimum traceability for the production process, the curves, results
and statistical evaluations of all measured processes can be saved and dis-
played on the screen. This does
not
occur automatically with the “Save pa-
rameters” function, you must set the save procedure in the
Data storage
win-
dow.
TIP
Select the memory directory under “File
−
> Specify memory directory”.
The saved data can then be displayed by the PME Assistant or imported into
other programs (e.g. Excel).
Step 1
Step 2
Step 3
Step 1 (storage target):
To save data to the PC, select the storage target “External via CAN/Ethernet”.
Step 2 (results):
Specify here which results should be saved (OK, NOK, all, none).
Step 3 (curves):
Specify here which curves should be saved (OK, NOK, all, none).
Calling up saved data / Report printout:
(
Display saved data
window)