![HBM HBK U93 Mounting Instructions Download Page 5](http://html1.mh-extra.com/html/hbm/hbk-u93/hbk-u93_mounting-instructions_2111874005.webp)
3
U93
SAFETY INSTRUCTIONS
1
SAFETY INSTRUCTIONS
Designated use
The force transducers in the U93 type series are solely designed for measuring (static
and dynamic) tensile and dynamic compressive forces within the load limits specified by
the technical data for the respective maximum capacities. Any other use is not the desig
nated use.
To ensure safe operation, the regulations in the mounting instructions, together with the
following safety requirements, and the data specified in the technical data sheets, must
be complied with. It is also essential to observe the applicable legal and safety regula
tions for the application concerned.
The force transducers are not intended for use as safety components. Please also refer
to the section: “Additional safety precautions”. Proper and safe operation of the force
transducer requires proper transportation, correct storage, siting and mounting, and care
ful operation.
Loading capacity limits
The data in the technical data sheet must be complied with when using the force trans
ducer. In particular, the respective maximum loads specified must never be exceeded.
The following limits set out in the technical data sheets must not be exceeded
S
Limit loads
S
Lateral load limits
S
Breaking loads
S
Permissible dynamic loads
S
Temperature limits
S
Limits of electrical loading capacity
Please note that when several force transducers are interconnected, the load/force dis
tribution is not always uniform.
Use as a machine element
The force transducers can be used as machine elements. When used in this manner, it
must be noted that, to favor greater sensitivity, the force transducer cannot be designed
with the safety factors usual in mechanical engineering. Please refer here to the section
“Loading capacity limits”, and to the specifications.
Accident prevention
The prevailing accident prevention regulations must be taken into account, even though
the nominal (rated) force values in the destructive range are well in excess of the full
scale value.
Summary of Contents for HBK U93
Page 3: ...U93 ENGLISH DEUTSCH FRAN AIS ITALIANO Mounting Instructions...
Page 23: ...U93 ENGLISH DEUTSCH FRAN AIS ITALIANO Montageanleitung...
Page 44: ...U93 OPTIONEN 22...
Page 45: ...U93 ENGLISH DEUTSCH FRAN AIS ITALIANO Notice de montage...
Page 66: ...U93 OPTIONS 22...
Page 67: ...U93 ENGLISH DEUTSCH FRAN AIS ITALIANO Istruzioni per il montaggio...
Page 88: ...HBK Hottinger Br el Kjaer www hbkworld com info hbkworld com A02081 03 YI0 02 7 0111 0005...