17
HLCM
SPECIFICATIONS
10.2
Load cells HLCB...
Type
HLC ... D1
Accuracy class according to OIML R 60
D1
Maximum number of load cell intervals
(n
LC
)
1000
Maximum capacity (E
max
)
110 kg
220 kg
550 kg
1.1 t
1.76 t
2 t
2.2 t
4.4 t
Minimum LC verification interval
(v
min
)
%
of E
max
0.0285
Sensitivity (C
n
)
mV/V
1.94
2.0
1.94
Sensitivity tolerance
%
± 0.5000
Temperature effect
on zero balance (TK
0
)
% of C
n
/
10 K
± 0.0400
Temperature effect
on sensitivity
(TK
C
)
± 0.0500
Hysteresis error (d
hy
)
% of C
n
± 0.0500
Non‐linearity (d
lin
± 0.0500
Creep (d
cr
) over 30 min.
± 0.0500
Input resistance (R
LC
)
Ω
> 350
Output resistance (R
0
)
350 ± 2
Reference excitation voltage
(U
ref
)
V
5
Nominal range of excitation volt
age (B
U
)
0.5 ... 15 ( Ex‐Versions max. 12 V)
Insulation resistance (R
is
)
GΩ
> 5
Nominal temperature range (B
T
)
°
C [
°
F]
-10 ... +40 [+14 ... +104]
Service temperature range (B
tu
)
-30 ... +70 [-22 ... +158]
Storage temperature range (B
tl
)
-50 ... +85 [-58 ... +185]
Summary of Contents for HLCM
Page 1: ...HLCM ENGLISH DEUTSCH FRAN AIS Mounting Instructions Montageanleitung Notice de montage...
Page 3: ...HLCM ENGLISH DEUTSCH FRAN AIS Mounting Instructions...
Page 23: ...HLCM ENGLISH DEUTSCH FRAN AIS Montageanleitung...
Page 43: ...HLCM ENGLISH DEUTSCH FRAN AIS Notice de montage...
Page 64: ...HBK Hottinger Br el Kjaer www hbkworld com info hbkworld com A01140 05 Y00 00 7 0101 0086...