Assembly Instructions  M8099-EN 

 

Spare part Sonic transducer (O/ID T25604, T25604-1, T26260-2,  
T26327-2) 

 

 

  

Purpose 

  

Replacement of Sonic transducer (BB 1.x, BB 2.x) 

  

 

  

Precondition 

      

 

WARNING! 
Danger for unauthorized persons! 

Conversion work may only be carried out by 
specialist staff who have been trained accordingly. 

Therefore: 
–  Keep unauthorized persons away from the work 

area. 

   

 

   

 

NOTE! 

Knowledge of the Instruction Manual is a 
precondition for carrying outconversion work on the 
unit. 

   

 

  

Procedure 

      

 

DANGER! 
Danger to life caused by electric current! 

Touching conductive parts causes a direct danger 

to life. 

Therefore: 

–  For all work on the electrical system, for 

maintenance, cleaning or repair work, 
disconnect from the mains or disconnect all 
phases of the external power supply and secure 
them against being switched on again. Check 
unit is isolated from power supply. 

   

 

  

 

 

WARNING! 
Danger of crushing due to rolling away or 
tipping 

With an uneven floor or when the castors are not 
locked, there is a danger that the unit tips over or 
rolls away causing crushing. 

Therefore: 
–  Only install the unit on an even floor. 
–  Ensure that the castors are locked. 

   

 

Summary of Contents for M8099-EN

Page 1: ...tion for carrying outconversion work on the unit Procedure DANGER Danger to life caused by electric current Touching conductive parts causes a direct danger to life Therefore For all work on the elect...

Page 2: ...ated with the symbol 2 Main switch off remove the plug from the mains and empty the unit 3 Remove control cable to ext flow rate meter Flow 5 4 Detach the hexagon screw and remove ext flow rate meter...

Page 3: ...nplug cable of the sound transducer BB 1 x BB 2 x on slot X 301 x or X 302 x 8 Proceed as follows to assemble the new sound transducer BB 1 x BB 2 x Clean installation space of sound transducer especi...

Page 4: ...g 6 Rear side of the evaluation unit 10 Proceed as follows in order to attach the cover of the evaluation unit Connect the ribbon cable to the keyboard and attach the cover Attach screws Label 1 Fig 5...

Page 5: ...et corresponding parameter Flow rate ext 1 8 Calibration at Service Calibration Flow rate external 1 to 4 or Service Calibration Flow rate external 5 to 8 to ON The flow rate is calibrated automatical...

Page 6: ...et parameter Flow rate calibration at Service Calibration Flow rate to ON The flow rate is calibrated automatically Only in the case of water devices If present set the parameter Pressure relief at un...

Page 7: ...Sonic transducer oil up to 200 C 0 58 m T25065 2 1 03 Sonic transducer oil up to 200 C 0 58 m T26082 2 1 04 Sonic transducer water up to 180 C 0 58 m T26310 2 1 05 O ring FFKM 17x2 T25429 1 1 06 O ri...