background image

Haztec International Ltd ∙ Moorfield Road ∙ Leeds ∙ LS19 7BN ∙ UK 

T: +44(0)113 202 9115 

[email protected] ∙ www.haztec.uk

 

5-9406-99-X 
LED Message Sign

 

 

   M105 Issue 1.1 Created by: Technical  

    - 1 -                                                       July 2019 

 

 
 

 

Thank you for purchasing this Haztec product. Before proceeding with installation it is essential 
to read and understand this instruction booklet. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Warning! 
 

 

This product must be installed by persons competent in vehicle electrical installations 

 

Care  should  be  taken  to  ensure  that  water  ingress  cannot  occur  through  mounting  or 
wiring holes 

 

Regularly inspect the product to confirm correct operation 

 

DO NOT

 stare directly into the light it produces as permanent damage to the eyes may 

result 

 

Use only a mixture of mild soap and water to clean this product 

 

DO NOT

 direct a high-pressure water jet at this product 

 

DO NOT 

allow solvents, fuels or acetone-based cleaners etc. to come into contact with 

this product 

 

Basic Operating Specifications: 
 

Operating Voltage: 

12V or 24V 

(model dependant)

 

Maximum current draw: 

1A @ 12VDC 

Maximum current draw: 

0.5A @ 24VDC 

Main casing dimensions: 

573 (L) x 140 (W) x 45 (H) 

 

Wiring Instructions: 
 

Wire 

Connect to 

Function 

Red 

Positive [+] via fuse 

Main feed 

Black 

Negative [-] 

Earth/Ground 

 

 
 

 

LED Message Sign 

 

99 messages 

 

9 characters 

 

Choice of LED colour 

 

12V or 24V versions 

 

Summary of Contents for 5-9406-99-X

Page 1: ...ly inspect the product to confirm correct operation DO NOT stare directly into the light it produces as permanent damage to the eyes may result Use only a mixture of mild soap and water to clean this product DO NOT direct a high pressure water jet at this product DO NOT allow solvents fuels or acetone based cleaners etc to come into contact with this product Basic Operating Specifications Operatin...

Page 2: ... instructions for software installation If the software installation does not begin automatically browse to the contents of the USB and double click on the Setup USB file This will begin the installation process please follow the on screen instructions Once the software has successfully installed navigate to the programs folder and click on EasyProgrammer2009 Click on the icon EasyProgrammer2009 f...

Page 3: ...he desired message appears in the editing screen Change the animation by clicking on the dropdown menus at the bottom of the screen MODE Select how the message enters and is displayed on the sign SPEED Controls the speed at which the message animates onto the screen STOP Sets the amount of time in seconds each line of the message is displayed before moving to the next OPTIONS Additional display op...

Page 4: ...ndset and LED display by turning the rocker switch to the ON position Select a message to display using the Up and Down buttons and scroll through the downloaded messages until the required message appears on the LCD screen To send and display the message press ENTER The handset will confirm that the message is sent with a single BEEP The selected message will now appear on the LED display until s...

Page 5: ...Haztec International Ltd Moorfield Road Leeds LS19 7BN UK T 44 0 113 202 9115 info haztec uk www haztec uk 5 9406 99 X LED Message Sign M105 Issue 1 1 Created by Technical 5 July 2019 ...