Starting/Priming the Pump 

 

 

Release all pressure from filter, pump, and piping system.  

See filter owner’s manual.

 

 

WARNING – 

Return to filter to close the manual air relief valve when a steady stream of water (not air or air 

and water) is discharged from the valve.  Failure to do so could result in personal injury or death.   

 

 

If water source is higher than the pump, pump will prime itself when suction and outlet valves are opened.  If water 
source is lower than the pump, unscrew and remove strainer cover; fill strainer housing with water. 

 

ATTENTION- 

NEVER OPERATE THE PUMP WITHOUT WATER.  

Water acts as a coolant and 

lubricant for the mechanical shaft seal.  NEVER run the pump dry.  Running the pump dry may damage seals, 
causing leakage, flooding and voids the warranty.  Strainer housing must be filled prior to starting.  

 

 

 

Clean and lubricate strainer cover O-ring with "Jack's 327" each time it is removed.  Inspect O-ring and re-install on 
strainer cover. 

 

Replace strainer cover on strainer housing; turn clockwise to tighten cover. 

       NOTE - Tighten strainer cover lock ring by hand only (no wrenches).

 

 

Verify that there are no leaks from the pump or filter.  If leakage occurs DO NOT start pump.  If no leakage occurs, 
stand at least 10 feet from pump and/or filter and proceed with next step.   

 

Pump is self-priming using 1 ½” pipe.  Turn on power and wait for pump to prime, which may take up to five (5) 
minutes.  Priming time will depend on vertical length of suction lift and horizontal length of suction pipe. If pump 
does NOT prime within five minutes, stop motor and determine cause.  Be sure all suction and discharge valves are 
open when pump is running.  See Troubleshooting Guide. 

 

 

 

ATTENTION –

 

Wait five (5) seconds before re-starting pump after stopping the pump.  Failure to do so may 

cause reverse rotation of motor and consequent serious pump damage.

 

 

Close filter manual air relief valve after pump is primed. 

 

Maintenance 

 

 

Clean strainer basket regularly.  Do NOT strike basket to clean.  Inspect strainer cover gasket regularly and replace as 
necessary. 

 

Hayward pumps have self-lubricating motor bearings and shaft seals.  No lubrication is necessary. 

 

Keep motor clean.  Insure air vents are free from obstruction to avoid damage.  Do NOT use water to hose off motor. 

 

Occasionally, shaft seals must be replaced, due to wear or damage.  Replace with genuine Hayward seal assembly kit.  
See “Shaft Seal Change Instructions” in this manual. 

 

 

Storage/Winterization 

 

  

WARNING – 

Separation Hazard.  

Do not purge the system with compressed air.  Purging 

the system with compressed air can cause components to explode, with risk of severe injury or death to 
anyone nearby.  Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, 
filter, or piping. 

 
 

 

  

ATTENTION

 

 

Allowing the pump to freeze will void the warranty.

 

 

  

ATTENTION –

 

Use ONLY propylene glycol as antifreeze in your pool/spa system.  Propylene glycol is non-

toxic and will not damage plastic system components; other anti-freezes are highly toxic and may damage plastic components 
in the system.

 

 

Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see 
instructions below).   
Keep motor dry and covered during storage.  To avoid condensation/corrosion problems, do NOT cover or wrap pump with 
plastic film or bags.

 

Summary of Contents for Max-Flo™

Page 1: ...122 degrees F an elevated base for improved motor cooling and to prevent flooding The Max Flo II is an ideal choice for both new construction or as a replacement pump To prevent potential injury and t...

Page 2: ...nnot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is...

Page 3: ...outlets and or suction outlet covers which are damaged broken cracked missing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become ent...

Page 4: ...operate pool and spa circulation system if a system component is not assembled properly damaged or missing Do not operate pool and spa circulation system unless filter air relief valve body is in loc...

Page 5: ...o meet all local and national codes Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints The base MUST be solid level rigid and vibration free...

Page 6: ...s Use care when using Teflon tape as friction is reduced considerably do NOT over tighten fitting or you may cause damage If leaks occur remove connector clean off old Teflon tape re wrap with one to...

Page 7: ...mming pool spa or hot tub and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING All electrical wir...

Page 8: ...uction pipe If pump does NOT prime within five minutes stop motor and determine cause Be sure all suction and discharge valves are open when pump is running See Troubleshooting Guide ATTENTION Wait fi...

Page 9: ...4 exposing the diffuser item 9 Remove the two diffuser screws item 7 and pull the diffuser off of the seal plate item 13 to expose the impeller item 10 Removing the Impeller See Parts Diagram on page...

Page 10: ...the diffuser item 9 over the impeller item 10 onto the seal plate item 13 aligning the three 3 protruding pins with the matching holes in the seal plate item 13 Note Arrow on diffuser item 9 will face...

Page 11: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Max Flo II Series __________________ ____________________________ Page 11 of 16 Replacement Parts Parts Diagram SEE PARTS LISTING ON NEXT PAGE Item 16 Option...

Page 12: ...thru 1 HP 1 SPX2700BE Diffuser 2 HP 1 10 SPX2700C Impeller for HP Max Rate Pump 10 SPX2707CM Impeller for 1 HP Max Rate Pump 10 SPX2710CM Impeller for 1 HP Max Rate Pump 10 SPX2715CM Impeller for 2 HP...

Page 13: ...mp strainer housing is filled with water and cover o ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring is lubricated with Jack s 327 and that strainer cover is lo...

Page 14: ...ir leak in suction piping cavitations caused by restricted or undersized suction line or leak at any joint low water level in pool and unrestricted discharge return lines Solution Correct suction cond...

Page 15: ...g the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 90 days of the receipt of defective...

Page 16: ...www haywardpool com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Max Flo II Series ___ Page 16 of 16 This Page is Blank...

Reviews: