background image

www.haywardpool.com              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

Max-Flo II

 Pump Series __________ 

           _____                 ________________________ Page 4 of 16           

 

 

WARNING

 – 

Hazardous Pressure.

  Pool and spa water circulation systems operate under 

hazardous pressure during start-up, normal operation, and after pump shut-off.  Stand clear of circulation 
system equipment during pump start-up.  Failure to follow safety and operation instructions could result in 
violent separation of the pump housing and cover due to pressure in the system, which could cause property 
damage, severe personal injury, or death.  Before servicing pool and spa water circulation system, all 
system and pump controls must be in off position and filter manual air relief valve must be in open 
position.  Before starting system pump, all system valves must be set in a position to allow system water to 
return back to the pool.  Do not change filter control valve position while system pump is running.  Before 

starting system pump, fully open filter manual air relief valve.  Do not close filter manual air relief valve until a steady stream of water 
(not air or air and water) is discharged.  All suction and discharge valves

 MUST 

be

 OPEN 

when starting the circulation system.  

Failure to do so could result in severe personal injury and/or property damage.   
 

 

WARNING

 –

 

Separation Hazard.

  Failure to follow safety and operation instructions could 

result in violent separation of pump components.  Strainer cover must be properly secured to pump housing 
with strainer cover lock ring.  Before servicing pool and spa circulation system, all system and pump 
controls must be in off position and filter manual air relief valve must be in open position.  Do not operate 
pool and spa circulation system if a system component is not assembled properly, damaged, or missing.  Do 
not operate pool and spa circulation system unless filter air relief valve body is in locked position in filter 
upper body.  All suction and discharge valves

 MUST 

be

 OPEN 

when starting the circulation system.  

Failure to do so could result in severe personal injury and/or property damage.  

 

 

 

WARNING

 – 

Never operate or test the circulation system at more than 50 psi.   

 

 

 

WARNING

 – 

Fire and burn hazard.

  Motors operate at high temperatures and if they are not properly isolated from 

any flammable structures or foreign debris they can cause fires, which may cause severe personal injury or death.  It is also necessary 
to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk for burns.

     

 

 

WARNING

 – 

Failure to

 

install according to all defined instructions may result in severe personal injury or death.

    

   

General Information 

 

Introduction 

 

This manual contains information for the proper installation and operation of the Hayward Max-Flo II

TM

 Series.  The 

instructions in this manual 

MUST

 be followed precisely.  

Failure to install according to defined instructions will void 

warranty. 

 

 

Product Features & Benefits 

• 

Self-priming. 

• 

Tri-Lock cam and ramp strainer cover are designed to seal with less than quarter turn. 

• 

Clear strainer cover lets you see when the basket needs cleaning.  Pressure testable to 50 psi 
MAXIMUM. 

• 

Large leaf holding capacity strainer basket extends time between cleanings. 

• 

Heavy-duty, high performance motor is designed to operate in environments up to 122° F. 

• 

Elevated base insures better air circulation for cooler running and prevents flooding. 

• 

All components molded of corrosion-proof reinforced engineered plastic for extra durability and long 
life. 

• 

Service-Ease Design provides easy access to all internal components by just removing 4 bolts. 

 
 
 
 
 
 

 

Summary of Contents for Max-Flo™

Page 1: ...122 degrees F an elevated base for improved motor cooling and to prevent flooding The Max Flo II is an ideal choice for both new construction or as a replacement pump To prevent potential injury and t...

Page 2: ...nnot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is...

Page 3: ...outlets and or suction outlet covers which are damaged broken cracked missing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become ent...

Page 4: ...operate pool and spa circulation system if a system component is not assembled properly damaged or missing Do not operate pool and spa circulation system unless filter air relief valve body is in loc...

Page 5: ...o meet all local and national codes Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints The base MUST be solid level rigid and vibration free...

Page 6: ...s Use care when using Teflon tape as friction is reduced considerably do NOT over tighten fitting or you may cause damage If leaks occur remove connector clean off old Teflon tape re wrap with one to...

Page 7: ...mming pool spa or hot tub and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING All electrical wir...

Page 8: ...uction pipe If pump does NOT prime within five minutes stop motor and determine cause Be sure all suction and discharge valves are open when pump is running See Troubleshooting Guide ATTENTION Wait fi...

Page 9: ...4 exposing the diffuser item 9 Remove the two diffuser screws item 7 and pull the diffuser off of the seal plate item 13 to expose the impeller item 10 Removing the Impeller See Parts Diagram on page...

Page 10: ...the diffuser item 9 over the impeller item 10 onto the seal plate item 13 aligning the three 3 protruding pins with the matching holes in the seal plate item 13 Note Arrow on diffuser item 9 will face...

Page 11: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Max Flo II Series __________________ ____________________________ Page 11 of 16 Replacement Parts Parts Diagram SEE PARTS LISTING ON NEXT PAGE Item 16 Option...

Page 12: ...thru 1 HP 1 SPX2700BE Diffuser 2 HP 1 10 SPX2700C Impeller for HP Max Rate Pump 10 SPX2707CM Impeller for 1 HP Max Rate Pump 10 SPX2710CM Impeller for 1 HP Max Rate Pump 10 SPX2715CM Impeller for 2 HP...

Page 13: ...mp strainer housing is filled with water and cover o ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring is lubricated with Jack s 327 and that strainer cover is lo...

Page 14: ...ir leak in suction piping cavitations caused by restricted or undersized suction line or leak at any joint low water level in pool and unrestricted discharge return lines Solution Correct suction cond...

Page 15: ...g the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 90 days of the receipt of defective...

Page 16: ...www haywardpool com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Max Flo II Series ___ Page 16 of 16 This Page is Blank...