Hayward E-Command® 4 Operation Manual Download Page 1

www.haywardnet.com

092420A

Copyright © 2008 Goldine Controls

620 Division St.
Elizabeth, NJ  07207

Hayward

ECOMMAND 4

Automation

Operation Manual

HPC-4

HPC-4-ACT

HPC-4-RC

HPC-4-ACT-RC

for models

Summary of Contents for E-Command® 4

Page 1: ...www haywardnet com Hayward ECOMMAND 4 Automation Operation Manual HPC 4 HPC 4 ACT HPC 4 RC HPC 4 ACT RC for models ...

Page 2: ...ying the equipment A wire connector is provided on this unit to connect a minimum 8AWG 8 4 mm2 solid copper conductor between this unit and any metal equipment metal enclosures of electrical equipment metal water pipe or conduit within 5 feet 1 5m of the unit to connect the equipment assembly or spa to a circuit protected by a ground fault circuit interrupter One bonding lug for US models two for ...

Page 3: ... Menu 10 Configuration Menu 13 Quick How To Operate the Spa Manually 22 Guide Operate the Spa Automatically 22 Set the Heater Temperature 22 Set the Chlorinator Output 22 Start Stop Superchlorination 23 Program a Timeclock 23 Program a CountdownTimer 23 Enter Exit Service Mode 23 Troubleshooting Service Mode 24 Diagnostic Information Check System Indicator 24 Diagnostic Menu 25 Salt Level 25 Water...

Page 4: ...piecesofequipment upto3automatic valveactuators andaconventionalandsolarheater Bothmanualandautomatic programmed operation are available All of the control functions are programmed at the unit s display keypad Although the ECOMMAND 4 has no built in chlorinator feature it can control an external GoldlineAqua Rite or HaywardSwimpurechlorinator Water Air Solar 240 VAC Power Filter Pump Lights Aux 1 ...

Page 5: ...er pump on manuallyat8 00PM itwillruncontinuouslyuntilthenextdayat5 00PMatwhichtimeitwillturnoffand followthenormalprogramfromthenon Manuallyturningoffarelayworksinasimilarfashion Filter Pump Single Speed Filter Pump If the pump is currently off press the FILTER button to turn on the pump Pressing the FILTER button again will turn off the pump However if there is a heater in the system and itisope...

Page 6: ... systems The POOL SPA button has no function Pool and Spa systems without spa spillover In pool only mode the left LED next to the POOL SPA buttonisilluminated PressingthePOOL SPAbuttonwillswitchtheECOMMAND4tospa onlyopera tion right LED illuminated Pressing the POOL SPAbutton again will switch back to pool only Note thatthefilterpumpwillturnoffwhilethepool spavalvesareturning Pool and Spa systems...

Page 7: ...intheselectedmenu Multiple pushes of the button will rotate through all menu items and return to the starting point Onlymenuitemsthatareapplicabletoyourpoolwillappear Example if you don t have a spa then no spa related menu items will appear 3 Once a menu item has been selected above the current setting selection will ap pear flashing on the display Use the and or keys to change this selec tion So...

Page 8: ... off check system error filter speed settings menu spa heater1 temperature pool heater1 temperature spa solar temperature pool solar temperature superchlorinate spa chlorinator setting pool chlorinator setting spa high low speed pool high low speed day and time backlit display light beeper teach wireless remote wireless channel timers menu pool filter pump1 or hi speed pool filter pump2 or lo spee...

Page 9: ... position and the filter pump is running and the spa water temperature is less than the desired temperature setting If you have both solar heat and a conventional heater and the solar priority option is selected Configuration Menu then the conventional heater will only operate when solar heat is NOT available Pool Heater1 Off Adjust the desired pool temperature Off 65 F 66 F 103 F 104 F Off Move t...

Page 10: ...he programmed number of hours Spa Chlorinator 3 Adjust the desired chlorinator output for spa 0 1 2 3 9 10 15 20 95 100 Move to previous next menu item This setting will appear only if the system has been setup for external chlorinator and spa only or pool and spa It will determine the external chlorinator output when the system is operating in spa only mode The actual amount of chlorine introduce...

Page 11: ...in 5 increments 50 is default Set Day and Time Wednesday 10 37P Adjust the current day of the week Move to hours setting Set Day and Time 10 37P Set Day and Time Wednesday 37 Set Day and Time Wednesday 10 P Adjust the current hour including AM PM if applicable Adjust the current minute Move to minutes setting Move to previous next menu item Use this function to set the current day of the week and ...

Page 12: ...to the ECOMMAND 4 system During this procedure the wireless remote learns and remembers the ID code for the wireless base station connected to this particular ECOMMAND 4 unit and will reject messages with any other ID codes If Base NOT found is displayed then the ECOMMAND 4 can not communicate with the transmitter receiver base station attached to the main unit If NOT Successful is displayed then ...

Page 13: ...ms with spillover enabled the valves will automatically switch to spillover mode at the start of the filtration period For all other systems the valves will switch to the pool only position Refer to the text above for general notes regarding timeclock programming For two speed or variable speed pumps this setting will be the period of time when the pump runs at high speed the word Filter T1 in the...

Page 14: ...ower controlled byAux1 and orAux2 you will have to program those separately see page 12 This menu will appear only if the Lights are configured for timeclock The lights will turn on and off at the designated times The only override on this function is manual on off control by the Lights button This menu will appear only if the Lights are configured for countdown timer This setting is the time afte...

Page 15: ...ecause of freeze protection Super Chlorinate 24 hours Adjust Superchlorination period 1 96 hours Move to previous next menu item If external chlorination is enabled For larger pools or when you have an unusually high bather load a large amount of rain a cloudy water condition or any other condition that requires a large amount of chlorine to be introduced to the pool adjust the Superchlorination p...

Page 16: ...en Pool Only and Spa Spillover options default Move to previous next configuration menu Move to next menu item Move to next menu item or previous next configuration menu Move to previous next configuration menu if Pool and Spa is selected and if Spa Spillover is enabled Spa CountDn 00 30 Adjust time setting Manual On Off 0 05 0 10 0 15 default is 4 00 Move to next menu item if Pool and Spa is sele...

Page 17: ...ed default the return and suction pool spa valves function normally Filter Off Valve Change This menu appears only if Pool Spa setup is set to Pool and Spa Std When enabled default the filter pump will shut off for 35 seconds whenever the Pool Spa valves are turning The pump will NOT shut off when a heater is in Heater Cooldown mode Filter Config to view change Filter Pump 1 Speed Freeze Protect E...

Page 18: ...tion Speed This menu only appears if freeze protection is enabled and the pump is configured for 2 speed or variable speed pump operation This is the speed that the pump will run at during freeze protection operation Select high default or low speed operation Freeze Protection Temperature Select the temperature to be used for freeze protection Temperature is adjustable from 33ºF 42ºF 1ºC 6ºC 38ºF ...

Page 19: ...abled and Disabled default Solar Priority Move to previous next configuration menu Move to next menu item or previous next configuration menu Move to next menu item Move to next menu item if Solar is enabled if Solar is enabled Allow Low Speed Disabled Toggle between Enabled and Disabled default Move to next menu item or previous next configuration menu if Solar is enabled and 1 speed Filter is no...

Page 20: ... and low speed or all functions except dimmer relay for manual on off countdown timer and timeclock functions Lights Function Although designated as the Lights output the function of the lights relay is similar to the aux1 and aux2 relays If pool lights are wired to the lights relay some options including Solar function Low Speed of a 2 Speed Filter Pump Lights Interlock and Lights Freeze Protecti...

Page 21: ... Pump Speed This is the speed of the pump when the Lights output is on The choices are the Settings Menu speed and a speed that is unique to the Lights output only The default selection is Settings Menu This is the speed of the pump that has been selected in the Settings Menu for normal filter operation If an alternate speed is desired when the Lights output is on push or and select from Lowest to...

Page 22: ...n Dimmer is selected and the Aux1 output is manually turned on the and buttons adjust the level from 20 to 100 default The level is saved for the next time the aux1 output is turned from off to on Aux1 Interlock If Enabled this feature will override the function Manual On Off Countdown Timer Timeclock selected above and turn the aux1 off when filter pump is off first 3 minutes of filter pump opera...

Page 23: ...itch to the jets skimming for the last half of the hour Valve3 Filter the valve operates whenever the Filter relay is on Valve3 Lights the valve operates whenever the Lights relay is on Valve3 Aux1 the valve operates whenever the Aux1 relay is on Valve3 Aux2 the valve operates whenever the Aux2 relay is on Valve3 Interlock If Enabled this feature will override the function timeclock or in floor cl...

Page 24: ... Format 12 hour AM PM Units ºF and PPM Move to previous next configuration menu Move to previous next configuration menu Toggle between 12 hour AM PM default and 24 hour time format options Toggle between ºF and PPM default and ºC and g L Metric options Reset Config to Default Press Are you sure to proceed Config reset Confirmed Initiate reset of all configuration parameters Reset all configuratio...

Page 25: ...end of the spa period the ECOMMAND 4 will return to its normally programmed operation state Set the Heater Temperature or turn heater permanently off 1 Pressthe MENU buttonrepeatedlyuntil SettingsMenu isdisplayed 2 Press the button repeatedly until the Spa Heater1 or Pool Heater1 is displayed 3 Press the or buttons repeatedly to adjust the temperature If you adjust the tempera turebelow65ºForabove...

Page 26: ...stic Information Program a Countdown Timer 1 Pressthe MENU buttonrepeatedlyuntil TimersMenu isdisplayed 2 Press the button repeatedly until the xxx Timer where xxx is the parameter that you want to program is displayed 3 Use the and buttons to set the desired timer period Note A setting of 0 00 will display as manual on off The countdown automatic turn off function is disabled but manual operation...

Page 27: ...o service timed mode whichisverysimilartoservicemode exceptthattheECOMMAND4willautomaticallyreturntonormal operation after 3 hours During service timed operation the SERVICE LED will flash and the time remainingwillbedisplayedontheremotedisplay keypad s Pressingthe SERVICE buttonagain willreturntheECOMMAND4tonormal automatic operation Check System Indicator The CHECK SYSTEM LED will alert you when...

Page 28: ...r to theAqua Rite or Swimpure manual to correct error Air Sensor 94ºF Solar Sensor Short circuit Water Sensor Open circuit No function No function No function Move to previous next menu item Move to previous next menu item Move to previous next menu item If the sensor appears to operating properly then the temperature will be displayed If this temperature is not correct then check the placement of...

Page 29: ...26 ...

Page 30: ...27 ...

Page 31: ...resulting from failure to install operate or maintain the product s in accordance with the recommendations contained in the owners manual s 4 Problems resulting from failure to maintain pool water chemistry in accordance with the recommendations in the owners manual s 5 Problems resulting from tampering accident abuse negligence unauthorized repairs or alternations fire flood lightning freezing ex...

Page 32: ...092420A Copyright 2008 Goldine Controls 620 Division St Elizabeth NJ 07207 ...

Reviews: