background image

Aqua Plus Programming Flow Chart

092359D RevF

Copyright © 2010 Hayward

Automation and Chlorination

Installation Manual

for model

PL-PLUS

PL-PLUS-20

Aqua Plus

®

620 Division St.
Elizabeth, NJ  07207

www.haywardnet.com

denotes conditional items

default menu

day and time

water temperature

air temperature

chlorinator setting

salt level

reason pump is running (not scheduled)

inspect cell

reason hi-speed is running (not scheduled)

countdown time remaining

heater control status

system manual off

check system error

filter vsp speed/reason

lights/aux speed/reason

pH/ORP levels

settings menu

spa heater1 temperature

pool heater1 temperature

spa solar temperature

pool solar temperature

vsp speed settings

superchlorinate

spa chlorinator setting

pool chlorinator setting

day and time

backlit display light

beeper

teach wireless remote

wireless channel

maintenance menu

pH calibration wizard

clean probe wizard

timers menu

pool filter 1 or hi-speed 1

pool filter 2 or lo-speed 1

pool filter 3 or hi-speed 2
pool filter 4 or lo-speed 2

spa

lights
aux1
aux2

valve3

superchlorinate

diagnostic menu

chlorinator diagnostics

instant salt

pH/orp levels

flow switch

cell temperature sensor

water/pool sensor

air sensor

solar sensor

vsp speed/power

main software revision

display software revision

chemistry sense module software

vsp software revision

RF base software revision

6 button spa side software revision

configuration menu

chlorinator

chemistry config. Wizard

pool/spa

filter

heater1

solar

external input active state

lights
aux1
aux2

valve3

6 button spa side remote

remote menus

7-day or weekend/weekday timeclock

12 hour or 24 hour time format

ºF or ºC

vsp speed (% or rpm)

reset to default

Summary of Contents for Aqua Plus Controls plus Chlorination

Page 1: ...chlorinator setting day and time backlit display light beeper teach wireless remote wireless channel maintenance menu pH calibration wizard clean probe wizard timers menu pool filter 1 or hi speed 1 p...

Page 2: ...totheoriginalowner Proofofpurchaseisrequiredforwarrantyservice Ifwrittenproofofpurchaseisnotprovided themanufacturing date code will be the sole determinant of the date of installation of the product...

Page 3: ...ter control see Heater Control wiring page 13 Some heaters also have internal switches or jumpers that have to be set correctly for remote control opera tion refer to the heater manual and also Heater...

Page 4: ...raturesensors Remotedisplay keypad optional Valveactuators ifapplicable 1 30 Reset Config to Default Press Are you sure to proceed Config reset Confirmed Initiate reset of all configuration parameters...

Page 5: ...e disabled the only way to enable Remote Menus is to use the local display keypad All Timeclocks 7 day Move to previous next configuration menu Toggle between 7 day default and Weekend Weekday time op...

Page 6: ...educetheefficiencyofthesanitizationandresultinlowchlorine production Ahigh salt level can cause theAqua Plus to stop chlorinating The salt in your pool spa is constantly recycled and the loss of salt...

Page 7: ...tions Aux1 Pump Speed This is the speed of the filter pump when theAux1 output is on The default selection is Settings Menu This is the speed of the pump that has been selected in the Settings Menu fo...

Page 8: ...If enabled this feature will override the function Manual On Off Countdown Timer Timeclock selected above and turn the lights relay off when filter pump is off first 3 minutes of filter pump operation...

Page 9: ...all functions except solar dimmer relay super chlorinate and low speed for all functions except solar dimmer relay super chlorinate pH dispense low speed and group f pH dispense low speed and group o...

Page 10: ...olar system If the solar is operated by a valve then the Valve3 output must be setup for solar logic If the solar is operated by a pump then one of theAUX relays must be set up for solar logic Also th...

Page 11: ...speed filter pump is selected Heater1 If the heater is Enabled the heater relay will turn on when the water temperature is less than the desired temperature setting and the filter pump is running The...

Page 12: ...2 speed Filter is selected if Freeze Protect is enabled and Variable Speed is selected External Input Disabled Toggle between Enabled and Disabled default Move to previous next configuration menu Fil...

Page 13: ...d then the pool spa valves are not needed and pushing the POOL SPA button on the display keypad will have no effect If Pool and Spa is selected then the pool spa suction and return valve actuators sho...

Page 14: ...ypes Move to next menu item Move to next menu item Chlorinator Enabled Display Salt Chlor Config to view change Toggle between Display Salt default and Minerals Toggle between Chlorinator Enabled and...

Page 15: ...ce There are twoAquaPlusversionsthatrequiredifferentinstallationtechniques AquaPlussoperatingwithasoftwareversionless than 4 00 require the pigtail or pH dispensing device to be connected to an intern...

Page 16: ...pularheaters Generic Heaters 1 Wire heater to 120 240V power source per the instructions in the heater manual The Aqua Plus does NOT control the power going to the heater 2 WiretheAquaPlusdrycontacthe...

Page 17: ...ors TheAquaPlusutilizes10Kohmthermistortypesensors Threesensors watertemperature airtemperatureandsolar temperature areincluded IftheAquaPlusisbeingusedtocontrolasolarheatingsystem thesolarsensorisreq...

Page 18: ...pe Black RAYPAK RP2100 Drawing is for digital heater If heater is a millivolt analog run red wires from Fireman s Switch to heater relay 15 STA RITE Heater 1 Turn power off to heater 2 Remove upper ja...