Model 7501BLH/7501BL240H 

Hazardous Location Heated Blanket for 7501 Portable Eyewash 

 

 

 

INSTALLATION, OPERATION 

MAINTENANCE INSTRUCTIONS 

 

 

LIMITED WARRANTY

 

 

HAWS warrants that this specific product is guaranteed against defective material or poor 
workmanship for a period of 

one year from date of shipment

. HAWS liability under this 

warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, 
or part thereof, which shall appear to the Company upon inspection to be of defective 
material or not of first class workmanship, provided that claim is made in writing to Haws 
within a reasonable period after receipt of the product. Where claims for defects are made, 
the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS 
will not be liable for the cost of repairs, alterations or replacements, or for any expense 
connected therewith made by the owner or his agents, except upon written authority from 
HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective 
materials or poor workmanship, except for replacements, as provided above. Buyer agrees 
that Haws has made no other warranties either expressed or implied in addition to those 
above stated, except that of title with respect to any of the products or equipment sold 
hereunder and that HAWS shall not be liable for general, special, or consequential damages 
claimed to arise under the contract of sale. 
 
The emergency equipment manufactured by HAWS is warranted to function if installation 
and maintenance instructions provided are adhered to. The units also must be used for the 
purpose for which they were intended. This product is intended to supplement first-aid 
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this 
emergency equipment will prevent serious injury or the aggravation of existing or prior 
injuries

 

NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR 

GIVEN BY HAWS.

 

 

NOTE TO INSTALLER: Please leave this information with the Maintenance Department. 

SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS 
MODEL PLEASE CALL: 
 

      

TECHNICAL SUPPORT:

 

1-800-766-5612 

 

FOR CUSTOMER SERVICE:    

1-888-640-4297 

Summary of Contents for 7501BLH

Page 1: ...is agents except upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and t...

Page 2: ... a ground fault protection device 30mA GFCI for Heat Trace Electrical fault currents may be insufficient to trip a conventional circuit breaker Units are suitable for installation and use in Class 1 Division 2 Group B C D T6 Class 2 Division 2 Group F G NEMA TYPE 4 areas and MUST BE INSTALLED IN COMPLIANCE WITH LOCAL STATE AND OR FEDERAL CODES USING FLEXIBLE CONDUIT OR CABLE RATED FOR CLASS I II D...

Page 3: ...ower cord to terminal block referencing the supplied electrical drawing The cord and fittings selected must have the appropriate hazardous rating required for the installation location The Model 7501BL240H 7501BL240H must use a ground fault protection device 30mA GFCI for Heat Trace NOTICE MODEL 7501BLH 7501BL240H REQUIRES MINIMUM NEMA TYPE 4 COMPLIANT EQUIPMENT ALL POWER CONNECTIONS MUST BE MADE ...

Page 4: ...anket in accordance with 7501TH 7501T240H installation instructions IMPORTANT SAFETY NOTICE THE NATIONAL ELECTRICAL CODE REQUIRES GROUND FAULT EQUIPMENT PROTECTION ON EACH HEATING CABLE BRANCH CIRCUIT TO REDUCE THE RISK OF FIRE CAUSED BY DAMAGE OR IMPROPER INSTALLATION CIRCUIT BREAKERS SUCH AS SQUARE D QO EPD AND QOB EPD OR EQUIVALENT WITH A 30mA TRIP LEVEL SHOULD BE USED PLEASE SUBSTITUTE THESE B...

Page 5: ...ermostat and heater function by applying ice thermostat for approximately 3 5 minutes The heat trace cable should become warm to the touch when operating properly Thermostat is located on junction box 2 Eyewash water is above 100 F 38 C 1 a Ambient air temperature is above 100 F 38 C Relocate eyewash out of direct sunlight or excess ambient temperature b Shut off electric power All electric connec...

Page 6: ...6 INSTALLATION 5235 2018 CC FOR MODELS 7501BLH 7501BL240H 1 ALL MODELS MUST HAVE A GROUND FAULT PROTECTION DEVICE 30mA GFCI FOR HEAT TRACE ELECTRICAL CURRENTS MAY BE INSUFFICIENT TO TRIP A CONVENTIONAL CIRCUIT BREAKER ALL INSTALLATIONS MUST BE INSTALLED IN COMPLIANCE WITH LOCAL STATE AND OR FEDERAL CODES 2 ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO NEC CEC CODE USING FLEXIBLE CONDUIT OR CABLE...