APPENDIX
A
016-2005-008 Rev. A
43
APPENDIX A
CONNECTING VIRTUAL
TERMINAL TO ISOBUS
Contact a local equipment or Raven dealer for additional assistance with any adapter cables required for
connecting the Hawkeye® 2 nozzle control system to the virtual terminal (VT).
VIPER 4 ISOBUS ADAPTER CABLE
NOTE:
For 2012 - 2015 machines, the ISOBUS adapter cable (P/N 115-0172-247) is required for a ROS device
to interface with the Hawkeye® 2 nozzle control system. Refer to the Installation Manual provided
with the ROS device for additional assistance with installing a Raven display.
2016 and newer machines with an existing Viper 4 field computer may already have the ISOBUS
connected to the Viper 4.
Look for a cable connected to Port 5 on the back of the Viper 4 to verify. If present, the ISOBUS
adapter cable (P/N 115-0172-247) will not be used. There will be two 2-pin Deutsch connectors on the
existing console cable that need to be connected together to finish connecting the Viper 4 to the
ISOBUS.
1. Locate the top panel to the right of the operator seat in the vehicle cabin.
FIGURE 1. Upper Panel Right of the Operator Seat
2. Remove the panel cover to access the ISOBUS terminator and connections.
3. Locate the connection labeled “ISO Terminator” toward the rear of the exposed panel.
Summary of Contents for AGCO RoGator A Series
Page 8: ...CHAPTER 1 4 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...
Page 18: ...CHAPTER 2 14 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...
Page 20: ...CHAPTER 3 16 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...
Page 28: ...CHAPTER 4 24 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...
Page 52: ...CHAPTER B 48 Hawkeye 2 Installation Manual for AGCO RoGator A B Series RG900 RG1100 RG1300...