- Safety precautions
3.2.5 - Risk of burns and explosion
N.B.-:-A
CID
IS
NEUTRALISED
WITH
SODIUM
BICARBONATE
AND
WATER
.
• Do not store LPG bottles in a closed or poorly ventilated room.
• Do not store LPG bottles near naked flames or glowing embers.
• Never fill the bottle above the level ( 80 % of the total capacity).
• Do not forget to drain the bottle before refilling it.
• Never use pliers or a spanner to open or close the bottle valve. If a tool is required, the valve is
damaged. It must therefore be replaced. Consult your HAULOTTE Services® After Sales for this
purpose.
• In order to maintain LPG vapourisation at the highest level in cold climates, the level of LPG
above 50 % of capacity.
For any intervention on the power sources, wear glasses and protective clothes (acid spray).
• Do not work in an explosive or flammable atmosphere (spark, flame, etc.).
• Do not touch the hot parts of the hydraulic power (engine, filters, ec.).
• Do not use a tool to bridge the battery terminals with metallic objects.
• Do not service the battery close to a spark, naked flame, glowing tobacco (emissions of gas).
• Do not fill up the fuel tank, when the engine is running and/or close to a naked flame.
• LPG is inflammable and always under pressure.
• LPG can cause serious burns.