background image

 

 

Betriebsanleitung 

englisch 

Doc ID: M001-HE055 Stand: 2021-06-09 

 

 

 

 

 

 

 

 

Vibration monitoring unit 
Series HE055 

 

 

 
• 

Vibration velocity (mm/s, rms) 

• 

Vibration acceleration (g, rms) 

• 

Vibration acceleration (g, rms) 

• 

Temperature (°C) 

• 

Crest factor 

• 

Output 1: IO-Link or 
                Digital switching output 

• 

Output 2: Analogue current output 4…20 mA or 
                Digital switching output 

• 

Adjustable frequency range: 1 Hz … 1000 Hz 

Date of manufacture: 

 

 

Type description: 

 

 

Serial no.: 

 

 

 

 

 

 

Summary of Contents for HE055 Series

Page 1: ...tion velocity mm s rms Vibration acceleration g rms Vibration acceleration g rms Temperature C Crest factor Output 1 IO Link or Digital switching output Output 2 Analogue current output 4 20 mA or Digital switching output Adjustable frequency range 1 Hz 1000 Hz Date of manufacture Type description Serial no ...

Page 2: ...e product the instruction manual must be read and un derstood All rights reserved including rights to translation Subject to modifications Please contact the company with any questions HAUBER Elektronik GmbH Fabrikstraße 6 D 72622 Nürtingen Germany Tel 49 0 7022 21750 0 Fax 49 0 7022 21750 50 info hauber elektronik de www hauber elektronik de ...

Page 3: ...ensions 11 11 Connection 11 12 IO Link description of functionality 12 12 1 Introduction 12 12 2 Software parameterization service 12 12 3 General data 12 12 4 Measured values and process values 12 12 5 Outputs 12 12 6 Switching signals 13 12 7 Frequency ranges Filter settings 13 12 8 Maintenance Data 13 13 Installation and commissioning 14 13 1 General notes 14 13 2 Wiring diagram earthing concep...

Page 4: ... obtained in other languages The product is built according to the latest state of the art However hazards to people machin ery and systems can still arise as the result of improper handling unintended use or operation and maintenance by persons inadequately trained on the product All those who are involved in the installation operation and maintenance of the product in the operator s plant must r...

Page 5: ...page 13 Optional safety integrity level SIL1 5 Intended use The HE055 type is used exclusively for measuring mechanical vibrations and the temperature in machines and mechanical systems Its use is only permissible within the specifications stated in the data sheet Main fields of application Fans ventilators blowers electric motors pumps centrifuges separators generators turbines and similar oscill...

Page 6: ...ard the following information must be observed Electrical protection Devices must be protected by means of fuses circuit breakers overheating protection impedance limiting switches or similar to ensure protection against excessive power output if there is a fault in the device Protection must be ap plied to supply lines and switching lines A circuit breaker suitable for 30V 3A according to UL Stan...

Page 7: ...rs MTTF years Tab 1 General data 10 2 Electrical data Voltage supply 24 V DC 10 Current supply max 250 mA Output 1 Pin 4 Output signal 4 20 mA proportional to the measuring range Apparent ohmic resistance load max 500 Ω Switching outputs Output signal Digital I O Electrical execution PNP NPN configurable Output function Normally closed normally open low active high active Switching levels 0 V Low ...

Page 8: ...𝑣𝑚𝑎𝑥 𝑎𝑚𝑎𝑥 2𝜋𝑓 Fig 1 shows the operating range of the vibration monitoring unit which is limited by the maxi mum measurable vibration velocity in mm s depending on the frequency in Hz Fig 1 Operating range diagram 1 Frequency in Hz 2 Vibration velocity in mm s rms 3 Operating range of the vibration monitoring unit Reading examples Frequency Hz Maximum measurable Vi bration velocity mm s rms 250 93 ...

Page 9: ...equency response 1 Hz to 1 000 Hz The frequency response is recorded using two reference sensors 1 Hz 10 Hz laser sensor 10 Hz 1 200 Hz acceleration sensor Fig 2 Typical frequency response 1 Hz 1 000 Hz 1 Frequency in Hz 2 Amplification in dB ...

Page 10: ...M8 x 8 mm Incline 1 25 mm standard Assembly type Standing vertical or lying horizontal Measurement direction Along the fixing axis Max torque of the Sensor 8 Nm Max torque of the M12 un ion nut on the connector 0 4 Nm Weight ca 90 g Protection class Plug connection closed IP 66 67 Type 4X Enclosure Product is suitable for outdoor applications Ambient temperature TA 40 C TA 85 C Max humidity 100 Ta...

Page 11: ... with M12 connector All dimensions in mm 1 M12 connector 2 Width A F 24 3 Fixing 4 Measuring direction along the fixing axis 11 Connection Plug M12 4 pole Pin 1 L 24 V DC Pin 2 Out 2 4 20 mA or switching output Pin 3 L 0V GND Pin 4 Out 1 IO Link or switching output ...

Page 12: ...meters and adresses are listed comprehensively within the IO Link description file avai lable in the download section of our homepage This chapter only serves as an overview of the products functions 12 4 Measured values and process values Following measured values and process values can be monitored via IO Link continuously Effective value vibration velocity 0 01 mm s rms Effective value vibratio...

Page 13: ...default and only adjustable with the temperature measurement 0 K 20 K 12 7 Frequency ranges Filter settings Eight predefined frequency ranges can be selected 0 10 Hz 1000 Hz 1 10 Hz 500 Hz 2 10 Hz 100 Hz 3 10 Hz 50 Hz 4 1 Hz 1000 Hz 5 1 Hz 500 Hz 6 1 Hz 100 Hz 7 1 Hz 50 Hz 12 8 Maintenance Data Following data is available exclusively via IO Link and cannot be output via any other output Counter It...

Page 14: ...ps are amongst the most common problems in measurement set ups with sen sitive sensor technology These issues arise due to unintentional differences in potential in the electrical circuit between the sensor and evaluation unit Ensure that the earth connection is electrically secure According to the earthing concept the cable shielding is electrically connected to the sensor housing through the knu...

Page 15: ...ace Tool 24 mm wrench Work steps and instructions Screw vibration monitoring unit into the threaded hole of the mounting surface in a fric tion locked manner using a hex key The tightening torque should be 8 Nm The tightening torque of the M12 union nut of the plug connection must not exceed 0 4 Nm To obtain precise measurement values the vibration monitoring unit must be fixed to the mounting sur...

Page 16: ...rce and or supply Analogue signal disabled Enable analogue signal Discontinuity in connecting cable Replace connecting cable Fuse defective Replace fuse Connection has incorrect polarity Connection of correct pole Vibration monitoring unit defective Replace vibration monitoring unit Relay does not switch Wrong limit value set Set correct limit value No power supply Check power source and or supply...

Page 17: ...ronmental factors and mechanical damage during transport with the use of adequate packing The sensor may not be stored in ambient temperatures outside the permitted operating tempe rature The product contains electronic components and must be disposed of properly in accordance with local laws and regulations ...

Page 18: ...8 x 8 mm incline 1 25 mm Software parameter settings factory default Output 1 Output 2 001 002 4 20 mA 0 16 mm s rms 10 Hz 1000 Hz 003 4 20 mA 0 25 mm s rms 10 Hz 1000 Hz 004 4 20 mA 0 32 mm s rms 10 Hz 1000 Hz 005 4 20 mA 0 50 mm s rms 10 Hz 1000 Hz 006 4 20 mA 0 64 mm s rms 10 Hz 1000 Hz 007 4 20 mA 0 16 mm s rms 1 Hz 1000 Hz 008 4 20 mA 0 25 mm s rms 1 Hz 1000 Hz 009 4 20 mA 0 32 mm s rms 1 Hz ...

Page 19: ...w that relate to this decla ration meet the basic health and safety requi rements of the norms and directives below Product series HE050 HE055 Norms and directives EU Directive Norms 2014 30 EU EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 2014 34 EU EN 60079 0 2019 EN 60079 1 2014 EN 60079 11 2012 EN 60079 31 2014 Signature Nürtingen 15 04 2021 Place and date _______________________________ Tobias ...