3H50, 4H50
Maintenance
HATZ
101
Manual
Engine without A/C compressor
Overview
1
Alternator
2
Upper fixing screw on the generator
3
Lower fixing screw on the generator
4
Poly v belt
5
Fan blade
Procedure
Step
Activity
1
Undo fixing screws (2) and (3).
2
Turn the generator (1) in the direction of the arrow to the stop.
3
Remove the loose poly v belt (4) from the pulley.
4
Carefully lift the poly v belt over a fan blade. Turn the fan further
in the counterclockwise direction and lift the belt over the re-
maining fan blades until it is completely free.
5
Check the pulley for perfect condition. If the grooves are broken
off or bent, renew the damaged pulley.
6
Feed a new poly v belt over the fan blade in the same way from
the radiator side.
7
Lay the poly v belt over the pulleys wheels and tension (see
8.2.8 Checking the poly v belt, page 97
8
Mount the protective guard and belt protection again.