2-4L41C, 2-4M41(Z), 4L42C, 4M42
Maintenance
HATZ
93
Manual
Step
Activity
5
If there is no reaction, check the following:
▪ Electrical part; cable connections, etc.
▪ Indicator
▪ Function of the maintenance switch.
Mechanical air filter maintenance display
4
Generate a vacuum by sucking forcefully at the hose end.
The red field (1) engages.
5
After the function test, unlock the red field (1) by pressing the re-
set button (2).
After the function test
6
Replace the faulty parts.
7
Reattach the hose (3) of the exhaust manifold.
8
Mount the capsule and air guide parts again.
8.2.17 Renewing the poly v belt and checking the function of the switch-off
unit
NOTICE
i
When changing the belt:
▪
Always check the function of the switch-off unit. The switch-
off pin must emerge by spring force, or else the machine will
not switch off automatically if the belt tears.
▪
If the grooves are broken off or bent, renew the damaged
pulley.
▪
To be absolutely sure that you order the right poly v belt – in
terms of the length – it is recommended that you measure
the diameter of the fan-side pulley and use this as the basis
for your selection.
Belt types
Because of the different diameters of the fan-side pulleys, in combination
with different engine types and versions, various lengths of poly v belts are
used.
Type and engine
version
ID number
Belt length mm
Fan pulley
Ø mm
2L41C
502 031 00
920
72
All remaining types
and versions
501 415 00
910
64
Summary of Contents for 2-4L41C
Page 2: ......