background image

A6 

A6 

Photocell S

F

01 User Manual

I. Technical Specification

1.

Working voltage: 12~24VAC/DC

2.

Working current: 24VDC; emitter: ≤15mA        receiver: ≤30mA

3.

Photocell wavelength: 940nm

4.

Angle of opposite emission: ≤±5º

5.

Receiver range: ≥12m

6.

Working temperature: -20º

+60

7.

Relay contact loading capacity: 1A/30VDC

8.

Waterproof grade: IP54

9.

Size: 73*43*25mm

10.

Weight

67g

II. Safety Instruction

1.

For security, please read the user manual carefully before initial operation;

2.

Please be sure the power is off before connecting, the product is produced without fuse;

3.

It is used only for the manual remote control and wireless control equipment / system, this system must 

not endanger life or property during the running failure or its security risks have been eliminated;

4.

Please operate the product in effective receive range.

III. Picture Display

IV. Installation Instruction

1.

The product should be installed  more than 20cm upper  the ground, and the distance between emitter and 

receiver shall be more than 0.5 meters;

2.

Avoid direct sunlight to emitters and receivers among ±5º

, or other direct strong light;

3.

Avoid other photocell emitters within effective receive range;

4.

If  install  many  photo  cells  on  the  same  line,  can  install  receivers  on  two  ends  and  then  emitters  in  the 

middle back to back which can effectively avoid the third problem.

5.

Installation firmly in order to avoid signal bias of emitters and receivers which will easily cause mis-operation.

6.

Connecting power after checking no error of connecting lines, emitter LED lights, keep the CAP of emitter 

and receiver align, receiver LED off; When they are not align, receiver LED on.

7.

Connecting power after checking no error of connecting lines, the contact NO/COM of receiver connects

while NC/COM  disconnects.;  Keep  the  CAP  of  emitter  and  receiver align, NC/COM  connects  while 

NO/COM disconnects.; When they are not align, NO/COM connects while NC/COM disconnects.