background image

IMPORTANT SAFETY INFORMATION

Form No. TFC461RM-0108

1

For safe and proper operation, plug unit
into a properly grounded electrical outlet of
the

correct

voltage,

size,

and

plug

configuration. If the plug and receptacle do
not match, contact a qualified electrician to
determine and install the proper voltage and
size electrical outlet.

To avoid any injury or damage to the unit,
do not pull unit by power cord.

To prevent any injury, discontinue use if
power cord is frayed or worn.

To reduce the risk of fire, the appliance is to
be installed on a non-combustible surface
only. The appliance is to be installed on
floors or counters of non-combustible
construction with non-combustible flooring
and surface finish and with no combustible
material against the underside, or on non-
combustible slabs or arches having no
combustible material against the underside.
Such construction shall in all cases extend
not less than 12″ (305 mm) beyond the
equipment on all sides.

For safe and proper operation, the unit must
be located a reasonable distance from
combustible walls and materials. If safe
distances are not maintained, discoloration
or combustion could occur. Do not locate
unit under shelving or closer than 12″
(305 mm) from the ceiling.

To ensure proper operation and safety,
allow a minimum of 1″ (25 mm) clearance
along the rear of the unit and 2″ (50 mm)
clearance at the feed and discharge sides.

To avoid any injury, turn the power switch
OFF, unplug the unit from the power source,
and allow to cool before performing any
maintenance.

Unit is not waterproof. DO NOT submerge in
water. Do not operate if it has been
submerged in water. Do not steam clean the
interior or flood with water or liquid
solution.

WARNING

Some exterior surfaces on the unit will get
hot. Use caution when touching these areas
to avoid injury.

To avoid electrical shock or personal injury,
do not steam clean or use excessive water
on the unit.

To avoid any injury or damage, the unit
must be serviced by qualified personnel
only.

To avoid any injury or damage to the unit,
turn the power OFF at the fused disconnect
switch/circuit breaker and allow to cool
before performing any maintenance.

If service is required on this unit, contact an
Authorized Hatco Service Agent or contact
the Hatco Service Department at 800-558-
0607 or 414-671-6350; fax 800-690-2966; or
International fax 414-671-3976.

This product has no “user-serviceable”
parts. To avoid damage to the unit or injury
to personnel, use only Authorized Hatco
Service

Agents

and

Genuine

Hatco

Replacement

Parts

when

service

is

required.

Genuine Hatco Replacement Parts are
specified

to

operate

safely

in

the

environments in which they are used. Some
aftermarket or generic replacement parts do
not have the characteristics that will allow
them to operate safely in Hatco equipment.
It is essential to use Genuine Hatco
Replacement Parts when repairing Hatco
equipment. Failure to use Genuine Hatco
Replacement Parts may subject operators
of the equipment to hazardous electrical
voltage, resulting in electrical shock or
burn.

WARNING

IMPORTANT! Read the following important safety information to avoid personal injury or
death, and to avoid damage to the equipment or property.

Summary of Contents for THERMO-FINISHER TFC-461R

Page 1: ...to understand the contents of this manual please bring it to the attention of your supervisor Keep this manual in a safe location for future reference No opere este equipo al menos que haya le do y c...

Page 2: ...ner Information i Introduction i Important Safety Information 1 Model Designation 2 Model Descriptions 3 All Models 3 TFC 461R Model 3 TFC 461R L Model 3 Specifications 3 Plug Configuration 3 Electric...

Page 3: ...e performing any maintenance Unit is not waterproof DO NOT submerge in water Do not operate if it has been submerged in water Do not steam clean the interior or flood with water or liquid solution WAR...

Page 4: ...y hot upon removal use oven mitt protective clothing or pan gripper to remove CAUTION Do not remove the glass from the unit for cleaning purposes Doing so may cause injury or damage to the unit To avo...

Page 5: ...RNING NEMA L15 30P NEMA 6 50P Figure 3 Plug Configurations ELECTRICAL RATING CHART ALL MODELS Thermo Finisher conveyor food finisher models have an easy to clean interior constructed of stainless stee...

Page 6: ...559 mm TFC 461R L 63 7 8 29 3 8 22 1622 mm 746 mm 559 mm DIMENSIONS EXTERIOR DIMENSIONS EFFECTIVE FINISHING AREA Figure 4 Dimensions TFC 461R L D D B B F F TFC 461R A E C A E C TFC 461R TFC 461R L Wid...

Page 7: ...educe the risk of fire the appliance is to be installed on a non combustible surface only The appliance is to be installed on floors or counters of non combustible construction with non combustible fl...

Page 8: ...ng element will be on Example T35 35 seconds These values are adjustable from zero minutes to 9 minutes 59 seconds Values change by 1 second every time an arrow key is pressed Holding down an arrow ke...

Page 9: ...Down arrow key to scroll to desired setting 4 Press the Enter key to proceed to the next step 5 The display shows Upper Time Value Repeatedly press Up or Down arrow key to scroll to desired setting Ho...

Page 10: ...re pressed or the unit goes into AUTO OFF Mode NOTE Begin with an IDLE mode setting of 30 and adjust the program accordingly to achieve optimum performance 1 Simultaneously press hold the Up arrow key...

Page 11: ...enough adjust by pressing the Up arrow key Each time the Up or Down arrow key is pressed the valve will change by 0 1 of a second 2 Press the Enter key to save the new setting into memory CANCELLING...

Page 12: ...lation of supplied legs NOTE See RECOMMENDED FOOD FINISHING GUIDE for specific information 1 Plug unit into an electrical outlet of the correct voltage size and plug configuration See SPECIFICATIONS f...

Page 13: ...es see Figure 9 Most menu items will require the Lower Power Value to be set higher than the Upper Power Value Frozen or refrigerated food product can be heated in the unit Frozen items do not have to...

Page 14: ...that has accumulated on the glass Do not remove the glass from the unit for cleaning purposes Doing so may cause injury or damage to the unit WARNING WARNING CAUTION CAUTION 5 Remove any stains from...

Page 15: ...frozen 30 seconds 20 seconds PAN USED 18 457 mm perforated aluminum pizza pan Pizza 12 305 mm Thin Crust 30 6 minute 35 7 minutes Frozen 30 seconds 15 seconds PAN USED 18 457 mm perforated aluminum pi...

Page 16: ...inside of unit are tight and secure If secure replace Electronic Control Board Hatco part number 02 01 226 00 Check ON OFF switch If there is power to switch but no power out replace switch Wiring ope...

Page 17: ...necessary Check gear motor for power See PROGRAMMING THE UNIT and reset program settings With the unit unplugged and the element isolated from the circuit verify with an Ohmmeter that the element lea...

Page 18: ...OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT...

Page 19: ...NOTES Form No TFC461RM 0108 17...

Page 20: ...ercial Kitchen Services St Louis 314 890 0700 Kaemmerlen Parts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Com...

Reviews:

Related manuals for THERMO-FINISHER TFC-461R