INSTALLATION
Installing the Faucet with Font Assembly
Use the following procedure to install the faucet with font
assembly.
1. Using a hole saw, cut the appropriate openings in
the countertop for the faucet assembly and the font
assembly. Refer to “Countertop Cutout Dimensions” in the
SPECIFICATIONS section.
2. Apply a food-safe silicone sealant around the bottom edge
of the font assembly.
3. Place the font assembly into the cutouts. Make sure to
align the font stud with the font cutout and the faucet hole
with the faucet assembly cutout.
4. Place the stud washer followed by the stud nut onto the
font stud, and tighten against the bottom of the cutout.
5. Remove the mounting nut from the threaded pipe on the
bottom of the faucet assembly. Leave the decorative trim
ring and o-ring on the faucet assembly.
6. Pass the faucet assembly with the data line, two water
pipes, and vent pipe through the faucet hole in the font
assembly and through the countertop cutout from above.
Make sure the o-ring remains in position below the trim
ring on the faucet assembly and above the font assembly.
7. Pass the data line, two water pipes, and vent pipe through
the mounting nut and thread the mounting nut onto the
threaded pipe underneath the countertop. Do not tighten
completely.
8. Make sure the faucet assembly is positioned properly above
the font assembly, then tighten the mounting nut securely.
NOTE: Do not turn or twist the faucet assembly after final
installation.
9. Connect the G 3/4″ BSPP drain connection on the bottom
of the font assembly to the onsite drain system or use the
included drain tube components.
Drain
Tube
Countertop
Cutouts
Faucet Assembly
w/Extension
O-Ring
Trim Ring
Font Assembly
Font Stud
Stud
Washer
Stud
Nut
Mounting
Nut
Data Line
Installing the Faucet with Font Assembly
NOTE: Faucet with Font Assembly shown with extension piece.
Installing and Connecting the Tank Unit
Use the following procedure to install the tank unit in the
cabinet underneath the faucet assembly as well as to make
the connections to the faucet assembly.
NOTE: Do not place the tank unit in the cabinet until the
rear connections are complete. There may be limited
working space behind the tank unit once it is installed.
NOTE: Flush the cold water supply line thoroughly before
connecting to the water inlet fitting on the tank unit. This
will prevent sediment from entering the tank unit.
1. Connect a cold water supply line to the G 1/2ʺ BSPP water
inlet fitting on the back of the tank unit. Refer to “Preparing
for Installation” earlier in this section for water supply line
specifications.
2. Connect the data line from the faucet assembly to the data
port on the back of the tank unit. Tighten securely.
Faucet
Assembly
Tank Unit
Water Inlet
Fitting
Data
Port
Data
Line
Rear View of Tank Unit
3. Lift the tank unit into the cabinet.
• Be aware of the connected cold water supply line and
data line while placing the tank unit.
• Make sure there are minimum clearances of at least
51 mm (2ʺ) along the sides of the unit and 64 mm
(2-1/2ʺ) along the rear of the unit.
• Make sure there are no obstructions in front of the air
ventilation openings on each side of the unit.
Summary of Contents for FLOWMAX FM-5 Series
Page 19: ...FM5M_CN 1217 19 F M 5 T FLOWMAX T FM 5 Hatco FLOWMAX 5 1 3 I O 1 3 m 51...
Page 23: ...FM5M_CN 1217 23 1 2 3 4 5 O 6 O 7 8 9 G 3 4 BSPP P 1 G 1 2 BSPP 2 3 51 mm 2 64 mm 2 1 2...
Page 24: ...FM5M_CN 1217 24 4 5 a b c 6 a b 7 1 2 I O I 3 4 5 6 7 I O O...
Page 26: ...FM5M_CN 1217 26 65 95 C 150 200 F 1 2 2 3 4 5 5 15 1 15 1 2 4 3 1 4 2 5 4 5 6 I O I 1 2 3 3 4...
Page 27: ...FM5M_CN 1217 27 65 C 149 F 1 1 2 3 4 1 2 6 3 4 1 2 5 3 2 4 5 6 English 1 2 7 3 4 5...
Page 28: ...FM5M_CN 1217 28 1 2 8 3 1 2 4 5 10 30 95 C C 95 9848L 1 2...