HearthStone Quality Home Heating Products, Inc.
Luno Model #8160
E
LECTRICAL
C
ONNECTIONS
NOTE:
Open the valve compartment door on the
lower front of the unit to access electrical and gas
connections.
R
EMOTE
C
ONTROL
T
HERMOSTAT
The Luno 8160 comes equipped with a
programmable ON/OFF/Thermostat remote control.
We recommend the use of the thermostatic remote
for more comfortable performance, however you
may still override the thermostat by setting the
switch to “ON”. The thermostat controls the unit by
“calling for heat.” The thermostat turns the unit on
when the room is cold, and turns the unit off once
the room is warmed sufficiently. If desired, you can
use any wired wall thermostat in place of the remote.
You cannot use both the remote and a wall
thermostat simultaneously.
W irin g C o lo r K E Y :
B r
Y G
W
G
Y G
B r
W
G
R E M O T E
O N
O F F
W irin g D ia g ra m - L u n o 8 1 6 0
Figure 8: Luno 8160 Wiring Diagram
R
EMOTE
T
HERMOSTAT
P
LACEMENT
Place the thermostat transmitter in the same room or
living space as the unit. Since the transmitter is the
device measuring the temperature, you will want to
keep it off the floor and away from any influences
that may cause the temperature in the vicinity of the
thermostat to be unrepresentative of the room
temperature in general. Such influences might
include strong lighting, a heater vent from the central
heating system, or a nearby sunny or drafty window.
Do not place the thermostat transmitter directly
behind or too close to the unit, otherwise heat from
the unit will immediately satisfy the thermostat and
turn the unit off.
W
IRING
I
NSTRUCTIONS
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing. (Attention: Au moment
de l’entretien des commandes, étiquetez tous les
fils avant le débranchement. Des erreurs de
câblage peuvent entraîun fonctionnement
inadequate et dangereux.) The proper location of
wire connections is shown in Figure 87.
12