HARVER CN50LV-2kw Instruction Manual Download Page 1

 

 

SPLIT MAGNETIC INDUCTION 

WATER HEATER 

BY 

HARVER 

 

INSTRUCTION MANUAL 

CN50LV-2kw + 2kw  

CN75LV-2kw + 2kw  

 

 

Summary of Contents for CN50LV-2kw

Page 1: ...SPLIT MAGNETIC INDUCTION WATER HEATER BY HARVER INSTRUCTION MANUAL CN50LV 2kw 2kw CN75LV 2kw 2kw ...

Page 2: ...efully before using the unit and keep this manual for future reference CONTENTS PRODUCT INFORMATION PAGE 2 SAFETY PRECAUTIONS PAGE 3 INSTALLATION PRECAUTIONS PAGE 4 TROUBLE SHOOTING CODES PAGE 5 TECHNICAL SPECIFICATIONS PAGE 5 HEATING TIMES PAGE 5 INSTALLATION INSTRUCTIONS PAGE 6 7 Page1 ...

Page 3: ...trical supply to the generator is converted into a magnetic energy that then causes a resistance field which in turn heats the water This means that there is no direct electrical a c current in close proximity to the water making it safer The unit uses new temperature sensing technology that is more accurate There is a high density thermal insulation layer to sustain the water temperature All thes...

Page 4: ...ons with pacemakers please consult your doctor before using It is recommended to remove the drain plug to remove the dirty water annually Place unit out of reach of children and make sure children are supervised in the use of the hot water People that are mentally challenged or physically handicapped must be supervised in the operation of this unit If there any defects or malfunction that are not ...

Page 5: ...3 INSTALLATION PRECAUTIONS DO NOT ATTEMPT TO INSTALL THE UNIT AS PER THE PICTURES BELOW THE UNT WILL NOT OPERATE CORRECTLY AND WILL CAUSE A DRY BURN ERROR THE WARRANTY WILL BE NULL AND VOID Page 4 ...

Page 6: ...E6 Unable to read temperature output 6 TECHNICAL SPECIFICATIONS 7 HEATING TIMES Page 5 Unit 50 Litre 75 Litre Power supply 230V 50Hz 230V 50Hz Rated Power 2kw 2kw 2kw 2kw Rated Current 9amp 9 amp 9 amp 9 amp Water pressure 600 kpa 600 kPa Waterproof Level IPX4 IPX4 Dimensions mm 440 x 1180 x 240 440 x 1550 x 240 Time to heat water per 1 deg Unit 50 Litre 75 Litre 2KW 2kw 2kw 0 7 min 1 2 min ...

Page 7: ...START 65 SHOWS ON DIGITAL READOUT FOR 5 SEC TEMP SHOWS AFTER 5 SEC 6 UNIT WILL HEAT TO 65 C TO ADJUST TEMP SETTING PRESS TEMP BUTTON TEMP SETTING WILL SHOW PRESS TO CHANGE TEMP SETTING BY 5 DEG FROM 40 75 DEG INSTALLATION DIAGRAM CN50LH CN75LH NOTE COLD WATER SUPPLY SHOULD COME FROM ABOVE UNIT TO PREVENT UNCONTROLLED DRAINAGE 1 THIS UNIT MUST BE INSTALLED AS PER THE DIAGRAM SANS 10254 2 THIS IS A ...

Reviews: