MAINTENANCE PRACTICES
61-00-36
Page 6-29
Rev. 2 Feb/17
Propeller Owner's Manual
136
7. Propeller Pitch Settings
A. High Pitch Stop
(1) The high pitch stop is set at the factory per the aircraft
manufacturer's recommendations. This stop is adjustable
only by
a certified propeller repair station with the
appropriate rating or the Hartzell Propeller Inc. factory.
B. Low Pitch Stop
(1) The low pitch stop is set at the factory per the aircraft
manufacturer's recommendations. This stop is adjustable
only by
a certified propeller repair station with the
appropriate rating or the Hartzell Propeller Inc. factory.
C. Reverse Pitch Stop
(1) The reverse pitch stop is set at the factory per the
aircraft manufacturer's recommendations. This stop is
adjustable only by a certified propeller repair station
with the appropriate rating or the Hartzell Propeller Inc.
factory.
8. Propeller Ice Protection Systems
A. Electric De-ice System
(1) Consult the Pilot Operating Handbook (including all
supplements) regarding flight into conditions of known
icing. The aircraft may not be certificated for flight in
known icing conditions, even though propeller de-ice
equipment is installed.
(2) Refer to the Anti-ice and De-ice Systems chapter of this
manual for operational checks of the de-ice system.
B. Anti-ice System
(1) Consult the Pilot Operating Handbook (including all
supplements) regarding flight into conditions of known
icing. The aircraft may not be certificated for flight in
known icing conditions, even though propeller anti-ice
equipment is installed.
(2) Refer to the Aircraft Maintenance Manual for
operational/functional checks of the anti-ice system.