-3-
-1-
-2-
TIMER
- Dual timers which start one after another for use in
training programs.
- Be used as ordinary countdown timer if 2nd timer is
not set
PACER
- Presettable from 10 beeps/minute to 320 beeps/minute
- Display of pacer frequency, beep counter elapsed
simultaneously
CHRONOGRAPH OPERATI ON
CLOCK
- Display of hour, minute, second, month, date, day, year
and alarm, auto calendar
- 12/24 hour format option
Depress D to select the operating mode.
The chronograph indicator "CHRONO"
is shown. And the memory balance
number is shown in the left up corner.
Depress A to start.
st
Depress B to read the 1 lap time. LAP is
shown at the upper row, SPLIT is shown
at the middle row and the
RUNNING CHRONO is shown at the
bottom row.
nd
Depress B to display the 2 lap time,
and the lap counter is shown in the left
up corner.
rd
Depress B to display the 3 lap time,
th
and depress B again to display the 4
lap time. Operate as above procedure,
the lap counters within 500 will be
shown.
Depress A to stop counting.
- Display of lap, split and running
chronograph
- Measure up to 9 hours 59 minutes and 59.99 seconds
- 500 recallable lap and split memories.
- Segregated memory (capability to memorise LAP time
of different races)
- Display of best (BES), slowest (SLO) and average
(AVE) lap time for the laps traversed.
- Lap counter (000-999)
- Data can be loaded to computer and printed
1 2 3
LAP TIME
SPLIT TIME
START
Thanks for purchasing this
professional stopwatch. Its
advanced Japanese CMOS,
combined scientific mechanical
theory makes sure your valuable
purchasing of a professional
stopwatch. Besides normal functions
of stopwatches,it has distinct advantage:
Segregated memory, data can be loaded
to computer and printed.
FEATURES
CHRONOGRAPH
A
D
B
B
D
B
A
A
C
B
D
Button A
Button B
Button C
Button D
RESET
LAP/SPLIT
SELECT
RECALL
START/STOP
SET
MODE
st
Depress C to recall the 1 lap data
during the RECALL mode.
nd
Depress C again to recall the 2 lap data.
C
C
-4-
-5-
If pressing and holding button A more
than 6 seconds, it will beep and
display ALL CLEAR Ed, and all the
stored data can be cleared.
-6-
rd
Depress C again to recall the 3 lap data.
NOTE:
1. Depress C to recall the current lap and split data directly
during the STOP or RUNNING mode.
2. When RECALL display, with each press of C, the stored
data are recalled successively in the following order:
Lap/split 1 2 3 500 STOP TIME
AVE BES SLO
3. If the lap or split time is greater than 9 hours 59 min 59.99
sec in any segregated period time, the AVE, BES and SLO
information will be disabled.
4. If the lap counter is greater than 500, the stored data more
than 500 should be deleted when calculate AVE, BES and
SLO.
Depress D to return the CHRONO to the
stopped status. Depress A to restart
counting or B to reset to "0".
NOTE:
1. After pressing button B to reset to "0",
press C button will enter into the
RECALL mode. The lower row will
display the segregated time number, the
middle and left up corner display year,
month, middle date, day and weekday.
The segregated time number stands for
the serial number of stored data. The biggest serial number
is the final memory and the smallest serial number is the
first memory. Press button B to select MCH (Memory
Chronograph), and then press button C to recall the
corresponding lap time record.
2. If there is no memory during counting, it can not go into
The stopwatch will give "BiBiBi" sound during clearing
the data.
C
D
B
A
B
A
software\English\JS-610P_CN.exe
to your hard disk (if not, you must insert CD every time
when printing)
DATA DOWNLOAD AND PRINTING
1. Software installation
1) Put the CD into the CD-ROM driver. Open file in route:
Driver\Win32 bit, Enter PL-2303 Driver Installer.exe, as
picture 1; click next , as picture 2; click finish .
2) Copy the program file (according to different language
version):
-
Chinese version
: software\chinese\JS-610P_CN.exe
-
English version:
" "
"
"
5. The stored memory can be recalled during the STOP or
RUNNING status.
6. If the lap counter in the left up corner line display "000 "
and flash, it means that the memory is already full. So
please clear the stored data as previously indicated before
using it again.
7. When there is segregated memory, AVE, BES, SLO and
STOP for every lap time take the total storage, so the lap
and split counters will be less than 500.
the RECALL mode when press C.
3. After reset the stopwatch to "0", press B to select
MCH and confirm that the serial number
after MCH is the memory you want to
delete. Then press and hold A button for
3 seconds to clear the current MCH data.
If the stored data is already cleared. It
will beep and display "Ed", and the serial
number will decrease 1 automatically.
-7-
-8-
-9-
TIMER OPERATION
Depress D button until th e stopwatch goes to the TR
mode. The top row is the display for the 1st timer
and the middle row is the display for the 2nd timer.
Press and hold B button for 2 seconds to
go into the SET TR mode with the hour
digit of the 1st timer blinking. Press A
button to set to desired hour for
countdown. Press B to go to the first
digit in minutes and press A to set
minutes. Similarly by using B and A
buttons, the desired countdown time for
the 1st and 2nd timer can be set.
Press A to start countdown with the
"1" at the top right corner blinking
PACER OPERATION
Depress D to select the PACER
mode.
The display will be as shown
with the last 2 digits at the lower
row blinking. At this status depress
B will sequence the PACER frequency as
follows: 10, 20, 30, 40, 60, 80, 120, 160, 200, 220,
240, 320
D
A
D
3) installation finished
2. Data printing
You can print the data, if there is lap/split memory
information in stopwatch.
1) Connect stopwatch to computer by transmission line
(If you have not installed the printing program, you will
see a dialog box NEW HARDWARE WAS
FOUND. Please close this dialog box
and back to Step 1: Software installation
to do it.)
2) Press D to choose printing style.
3) Double-click the program file:
610P_EN.exe (or Chinese version 610P_CN.exe). If
there is no this file now, please back to Step 2 of
software installation to copy the program file (Picture 3)
4) Press A to transmit the data to printing
window. When transmission finish,
there is END signal, as picture4.
(NOTE: If frequent transmission is not
needed, please do not Press A often. )
5) Finally, press FILE-> PRINT to execute
Picture 3
Picture 4
Picture 1
Picture 2
printing.
and the timer setting counting down. When the 1st
timer approaches zero, the timer gives 4 beeps and
the 2nd timer starts counting down immediately.
When the 2nd timer approaches zero, it gives 2
beeps and the 4 digit counter at the lowest row
advances by1 automatically. At anytime during
countdown, pressing A will stop counting.
Remark:
1. When the 1st timer is set ,it is default 10 hour.
When the 2nd timer is not set, it is default of
zero (not working).
2. If only the 1st timer is set, the timer is used as
an ordinary countdown time and will give
automatically when the timer reaches zero .
display and when not , will be not on the display.
When reach to alarm time it will sound for 60 seconds.
CARE OF YOUR STOPWATCH
WATER RESISTANCE
The stopwatch is designed to withstand accidental
contact with water such as splashes or rain, but it is not
designed for use in water. Do not operate the buttons
when the stopwatch is wet.
TEMPERATURE
Do not leave your stopwatch under direct sunlight or
in very high temperature for a long time, the display
may become black. Do not leave your stopwatch in
very low temperature as this may cause a slight time
loss or gain and the change of digits becomes slow. In
both cases the above conditions will be corrected when
the stopwatch return to normal temperature.
SHOCKS
Be careful not to drop your stopwatch or hit it against
hard surface, as it may cause a mechanical damage.
STATIC ELECTRICITY
The integrated circuit in your stopwatch can be
affected by static electricity. If the static electricity is
very strong, a permanent damage can occur. Be
" "
-10-
-11-
-12-
CLOCK AND ALARM TIME ADJUST
Depress D to select CLOCK mode.
The alarm hour, alarm minutes,
month, date, day, year, hour , minute
and seconds are displayed as shown.
Keep B pressed for 2 seconds to show
the clock setting display. The alarm time HOUR
digits start flashing. Time setting can be done by
means of depressing B to select digits and A to
advance digits.
NOTE: Alarm is automatically armed if alarm
hour or minute has been set. Alarm can also be
armed or disarmed by depressing C at normal time
mode. When alarm is armed will be on the
" "
D
Depress A to start PACER.
A beeping sound of 320 beeps/
minute will sound. The beep counter
is at the center and PACER
frequency is at the lower row. The
beep counter has a range of 9999.
Depress A to stop PACER.
NOTE: Pacer will be reset if stopwatch is
switched to another mode.
A
careful of the screen of the TV set and the wearing of
clothing made of synthetic material in dry weather;
in such cases a very strong static electricity can be
generated.
MAGNETISM
Not affected.
CHEMICALS
Do not expose your stopwatch to solvents such as
gasoline and alcohol, the spray of cosmetics, cleaners,
paints etc as they may cause damage to the stopwatch
When the display becomes dim or faded out, battery
replacement is necessary.
1. Unscrew and remove back cover.
2. Unscrew the battery contact and
take off the old battery.
3. Replace with fresh lithium battery
CR2032 or equivalent.
4. Before putting in the new battery
make sure that the triangular contact is in the
triangular slot under the battery, and screw the
battery contact.
5. Press button A, B, C, and D at the same time to reset.
6. Screw the back cover.
BATTERY REPLACEMENT
46-134
Instruction Manual
Professional Stopwatch